Empire Comfort Systems DVLXG75BP90N-1 Installer's Manual page 42

Direct vent zero clearance gas fireplace heater
Table of Contents

Advertisement

RETURN AIR
If outlets are placed in rooms other than that in which the
fireplace is located, a means of return air is required. This is to
equalize pressure and prevent back flow within the duct system.
This will also assist temperature regulation to these areas.
SECONDARY AIR INLET
Ensure the secondary inlet is connected to a suitable inlet vent/
grill.
Outlet Air
(warm)
Inlet Air
(cool)
8" Fexible Ducting
MAX 10ft
42
DUCT VENT INSTALLATION
DUCTING OUTLET PLACEMENT
To achieve even heat distribution, outlets should be positioned in
the corners of rooms furthest from the fireplace location.
Keeping a 1 inch clearance to allow full airflow.
1 Inch Clearance around vents
Inlet air needed for fireplace operation
FAN