Calibration - Roland EGX-600 Service Notes

Hide thumbs Also See for EGX-600:
Table of Contents

Advertisement

4 Adjustment
4-7 CALIBRATION (Referential Time : 20 minutes)
Attach the ZEC-A2025 and ACRYLIC PLATE (over 25cm x
1
19cm) to the machine.
4
Enter the SERVICE MODE by turning on the power while
2
pressing [
], [
under the [Check Mode XY-COMP. Z-COMP.] and press
[ENTER] key.
Set both [X COMP.] and [Y COMP.] to default [8333] and
press the [ENTER] to save the settings.
Turn off the power after setting is completed.
Turn on the power and set the other settings as shown
3
below.
Turn off the power after setting is completed.
SETTING :
HOME POSITION
ZO
Spindle RPM
Turn on the power while pressing [
4
[Calibration Mode].
EGX-600/400 engraves as the figure.
80
] and [
] keys and select [XY-COMP.]
: Left Lower Corner
: Surface of the material
: 8,000 rpm
] key to enter the
POWER ON
Check Mode
Check Mode
XY-COMP. Z-COMP.
X-COMP. Y-COMP.
<8333>
<8333>
8000rpm
5000rpm
15000rpm
230mm
190mm