Feed Calibration

Information

Necessary tools
General tools
SP-M (Matte-PET artificial paper)
Special tools
None
Typical work time
Contents of work

Feed calibration

Workflow

C AUTION
• This adjustment is for calibrating the feed amount of media. It allows the media to be fed in proper amount by calibrating
the variation in grit roller diameter. Calibration is made based on the value in feeding media [SP-M]. Without proper
calibration, it may cause misalignment in the feed amount of media, and it results in the problems such as white banding,
banding of overlap or the dimension error of print result compared to the original data.
• When you do not have SP-M, use PET film for solvents.
• Take-up unit must not be used during this adjustment.
1.
Connect Peck2 to the machine, and enter the service mode. Set SP-M on the printer.
2.
Select [PRINT MENU] > [CALIB.DEFAULT] > [TEST PRINT], and press the [ENTER] key.
C AUTION
Test print requires 510 mm or more of the media setup width.
SERVICE MENU
PRINT MENU
[ ]
PRINT MENU
CALIB.DEFAULT
[ ]
CALIB.DEFAULT
TEST PRINT
[ ]
Time
15 min.
[ ]
[ ]
2-65
2
SG2-640/540/300