4-10 Z Axis Load Check (Referential Time : 8 minutes)
Turn on the Power while pressing the [
1
keys to enter the Service Mode.
Select the [LOAD] menu by pressing the [MENU] key and
press [ENTER] key.
Select the [AXIS Z] in the [LOAD] menu and press [ENTER]
2
key. Then, Carriage moves to the Limit Position.
Enter the value 350 and press the [ENTER] key.
After setting the value, the load check starts.
3
The Carriage moves in the Z direction to check the load.
], [
], [
]
[ ], [ ], [ ] + POWER ON
[MENU] key
CHECK MODE
LOAD
CON.
CARD
[ENTER] key
AXIS
X Y Z S
[ENTER] key
AXIS
X Y Z S
VALUE 350
[ENTER] key
AXIS
X Y Z S
VALUE 350
OK
4 Adjustment
4
85