3 Replacement of Main Parts
3-5 X Axis LM Guide_Repalcement (Referential Time : 35 minutes)
NOTES
1. LM GUIDE has the direction for fixing. Bottom side of the LM GUIDE has the line that indicates its
direction and the side plane of the bottom part will be the standard plane.
Push the standard plane of the LM GUIDE against the standard plane of the machine when fixing the
LM GUIDE.
3
Remove the X Axis Rail Cover, Rail Cover and Right
1
Side Cover.
Remove the Junction Board Cover.
2
Then, remove the Limit Switch.
50
STANDARD PLANE of LM GUIDE
Top Side
Bottom Side
Line
Standard Plane
X Axis Rail Cover
Right Side Cover