4-12 CALIBRATION (FEEDING DIRECTION) (Referential Time : 20 min.)
This adjustment is for calibrating the feed amount of media. It allows the media to be fed proper
amount by calibrating the variation in Grit Roller diameter. Calibration is made based on the value in
feeding media [PET-G].
Without proper calibration, it causes misalignment in the feed amount of media, and results in the
problems such as white banding, banding of overlap or the dimension error of print result compared
to the original data .
Take-up unit must not be used during this adjustment.
Turn on the sub power switch while pressing [
1
[
] and [
] keys to enter the SERVICE MODE.
Set PET-G film on the machine.
2
Select [TEST PRINT] under [CALIB.DEFAULT] menu
3
and press [ENTER] key.
TEST PRINT requires 510mm or more of the
media Setup width.
],
[
] , [
] , [
MENU
SERVICE MENU
SERVICE MENU
PRINT MENU
PRINT MENU
CALIB.DEFAULT
CALIB.DEFAULT
TEST PRINT
4-55
] + SUB POWER ON
[MENU] key
[ ]
[ ]
[ ]
[ ]