3 Replacement of Main Parts
3-8 Y Belt_Repalcement (Referential Time : 30 minutes)
Remove the Y Rail Cover and the Front Cover.
1
3
Loosen the Screw1 and remove Screw2 and then loosen the
2
Nut2.
Then, remove the Belt from the Idle Pulley.
Loosen the 4 screws and remove the Belt from the Carriage
3
Rail Base.
Put the new Belt through the Belt Holder and tighten up the
Screws.
When putting the new Belt, be careful not to
overlap the both end of the Belt.
64
Front Cover
Belt
Screw1
Nut1
Screw2
Screws
Belt
Holder
Y Rail Cover
Frame
Nut2
Belt

Advertisement