4-9 CALIBRATION (FEEDING DIRECTION) (Referential Time : 20 min.)
This adjustment is for calibrating the feed amount of media. It allows the media to be fed proper
amount by calibrating the variation in Grit Roller diameter. Calibration of the machine is made based
on the value in feeding media [PET-G] (Roll media with a width of 1050mm.)
Without proper calibration, it causes misalignment in the feed amount of media, and results in the
problems such as white banding, banding of overlap or the dimension error of print result compared
to the original data.
Do not use the Take-up unit during this adjustment.
Turn on the Sub Power SW while pressing [
1
and [
] keys to enter the Service Mode.
Set PET-G film on the machine.
2
Select [PRINT MENU] > [CALIB.DEFAULT] > [TEST
3
PRINT] menu and press the [ENTER] key.
Test print requires 510mm or more of the media
Setup width.
], [
]
MENU
SERVICE MENU
SERVICE MENU
PRINT MENU
PRINT MENU
CALIB.DEFAULT
CALIB.DEFAULT
TEST PRINT
4-44
+