Panasonic Digital Business System - Programming Manual
April 1997
E&M trunk status
(1-12)#
Private circuit number
1-3 card 1
4-6 card 2
7-9 card 3
10-12 card 4
Determines whether or not a private circuit is used. When a circuit is set to not used the tell-tale
LED corresponding to it on the card will remain lit after system start up.
Related step
FF1 10# (1-10)# (1-4)# , Slot setting
E&M trunk group number
(1-12)#
Private circuit number
Assigns private lines to private line groups. Circuits must be assigned to groups as all E&M access
is via group access and not independent circuits.
AC15 Dial Mode
(1-12)#
Private Circuit number
1-3 card 1
4-6 card 2
7-9 card 3
10-12 card 4
The dialling type for AC15 lines can be set to tone or pulse using this step. If changed a system
power Off/On reset is required. If set for DTMF an DTMF receiver card is required in the CCU.
This step will only take effect if the circuit specified is supported by an AC15 card (VB3673) it has
no effect when E&M cards are installed.
FF2-3#-(1-12)#-1#-(0-1)#
FF2-3#-(1-12)#-2#-(0-3)#
FF2-3#-(1-12)#-3#-(0-1)# (P)
87
[TRUNK STATUS]
(0-1)#
0#: Used
1#: Not used
[TRUNK GROUP NO.]
(0-3)#
0#: Not assigned
1#: Group 1
2#: Group 2
3#: Group 3
[AC15 DIAL TYPE]
(0-1)#
0#: DTMF
1#: Pulse
Issue 15
3.1
3.1
CPC-EX 1.0