Panasonic DBS Series Programming Manual page 84

Digital business system
Hide thumbs Also See for DBS Series:
Table of Contents

Advertisement

Panasonic Digital Business System - Programming Manual
April 1997
AC15 minimum pause
(1-3)#
Private Circuit trunk group
Sets the minimum pause between dial pulses when making an Private Circuit call. The default
setting is for DBS to DBS connection and may require adjustment when the remote system is not
a DBS.
AC15 return confirmation monitor
(1-3)#
Private Circuit trunk group
Sets the interval between sending out the release signal to the other party and receiving the
release acknowledge signal after ending an internal call via the Private Circuit Card.
FF2-2#-(1-3)#-12#-(0-7)#
FF2-2#(1-3)#-13#-(0-7)#
84
[AC15 INTERDIGIT]
(0-7)#
0#: 300 msec
1#: 400 msec
2#: 500 msec
3#: 600 msec
4#: 700 msec
5#: 800 msec
6#: 900 msec
7#: 1000 msec
[AC15 RLS ACK]
(0-7)#
0#: 1 second
1#: 2 seconds
2#: 3 seconds
3#: 4 seconds
4#: 5 seconds
5#: 6 seconds
6#: 7 seconds
7#: 8 seconds
Issue 15
CPC-EX 1.0
CPC-EX 1.0

Advertisement

Table of Contents
loading

Table of Contents