E&M return detect timer
(1-3)#
E&M trunk group
This sets the time to detect the release signal
E&M anti collision timer
(1-3)#
E&M trunk group
This sets the time after E&M seizure in which both sending and receiving are prohibited to avoid
call collision between systems.
FF2-2#-(1-3)#-8#-(0-15)#
FF2-2#-(1-3)#-9#-(0-15)#
82
[RELEASE(E&M)]
(0-15)#
0#: 100 msec
1#: 150 msec
2#: 200 msec
3#: 250 msec
4#: 300 msec
5#: 350 msec
6#: 400 msec
7#: 500 msec
8#: 600 msec
9#: 800 msec
10#: 1000 msec
11#: 1100 msec
12#: 1300 msec
13#: 1700 msec
14#: 2300 msec
15#: 3500 msec
[GLARE (E&M)]
(0-15)#
0#: 10 msec
1#: 15 msec
2#: 20 msec
3#: 25 msec
4#: 30 msec
5#: 35 msec
6#: 40 msec
7#: 45 msec
8#: 50 msec
9#: 60 msec
10#: 70 msec
11#: 80 msec
12#: 90 msec
13#: 100 msec
14#: 110 msec
15#: 120 msec