8. Locate and unpack the replacement backplane.
Note: Hold the backplane by its edges. Do not handle any of its components.
9. Align and place the backplane hey holes over the alignment pins on the drive bay (see Letter A).
10. Push down on the backplane until fully seated within the tabs on the chassis base plate (see Letter B).
11. Using the one screw, secure the backplane to the drive bay (see Letter C).
12. Re-attach all cables to the backplane.
13. Reinstall all drives and/or drive blanks into the front drive bay.
Notes:
All front drive bays must be populated with an SSD or supplied drive blank.
If the front drives were configured as part of a RAID partition, ensure that all drive I/O cables and
drives were reinstalled to the same locations as they were configured before the procedure.
14. Reinstall the system top cover (see