7. Locate and carefully unpack the replacement backplane.
Note: Hold the backplane by its edges. Do not touch any components mounted to the backplane.
8. Align and lower the bottom edge of the backplane with the three tabs on the chassis base. See
119
(see Letter A).
9. Verify the alignment of the three backplane mounting holes with the threaded studs of the front drive
bay.
10. Secure the backplane with three screws as shown (see Letter B).
11. Re-attach all cables to the backplane.
12. Reinstall all drives and/or drive blanks into the front drive bay.
Notes:
All front drive bays must be populated with an SSD or supplied drive blank.
If the front drives were configured as part of a RAID partition, ensure that all drive I/O cables and
drives were reinstalled to the same locations as they were configured before the procedure.
13. Reinstall the system top cover (see
86

Figure 119. 4 x 2.5" Backplane Installation

Section
6.1.2).
Figure