Intel® Server System M50FCP2UR System Integration and Service Guide
2.5
Memory Module Installation
Required Tools and Supplies
Anti-static wrist strap and conductive workbench pad (recommended)
•
The Intel® Server System M50FCP2UR supports standard DDR5 RDIMMs, 3DS-RDIMMs, and 9x4 RDIMMs.
DIMMs are referred to as "memory module" in the following procedure.
Notes:
DIMM blanks should only be removed when installing a memory module in its place.
•
•
See
Appendix B
for memory population rules
1. Remove the DIMM blank from the desired memory slot:
Open the ejection tabs at both ends of the selected memory slot to lift the DIMM blank from the
•
slot (see Letter A).
Carefully remove the DIMM Blank from the system (see Letter B).
•
2. Ensure that ejection tabs at both ends of the module slot are pushed outward to the open position
(see Letter A).
Figure 24. DIMM Blank Removal
Figure 25. Memory Module Installation
33