Field
SCAICOMS table
The SCAICOMS table indicates what links are waiting for a call request and
who the link is expecting the call request from. Nortel recommends that you
configure the continuity audit interval (AUDINTVL) so that the check is not
performed more that once every 15 minutes.
LINKSET SCAILINKS OPTIONS
LAB8MPC1 X25 (MPC ( 0 3 111111111 0 0 0 0 SVC) $)$ MN CR N
(ENHASSOC 100) ( CONTAUD Y 15 5 10 N)$
Field
LINKSEL
SCAILNKS
Installation and Configuration Guide
Subfield or
Data Type/
refinement
Range
L3MODULO MOD8 or
MOD128
N2
1-255
T1_S
1-255
T2_S
0-255
Subfield or
Data Type/
refinement
Range
Alphanumeric.
Up to 16
characters.
Configuring LinkPlexer for X.25/CompuCALL
Explanation and action
Numbering scheme for
end-to-end messaging at
level 3. Maximum number
of unacknowledged
messages allowed at level
3. Default is MOD8.
Number of times to
retransmit a frame for
which there was no
acknowledgement
Timer 1 in 1 s steps
Timer 2 in 1 s steps. Keep
lower than T1_S.
Explanation and action
Name of linkset
SCAI link information