Nortel 1000 Configuration Manual page 147

Nortel 1000 servers: user guide
Table of Contents

Advertisement

6
Copyright © 2005-2007, Nortel Networks
.
Table 12 "Main office B DMI and RLI provisioning for calls in branch
office B" (page 147)
Table 12
Main office B DMI and RLI provisioning for calls in branch office B
Create a DMI
LD 86
REQ new
CUST 0
FEAT dgt
DMI 50
DEL 0
ISPN no
INST 741841
CTYP loc
Provision the main office with CDP DSC (mapped by the RLI into
Location Codes) sufficient to uniquely identify all of its branch offices
(using extended location codes, if required); use the RLI index
defined for each branch office as the RLI value of the LOC definition.
This is the route to the branch office.
Table 13 "Main office B LOC provisioning for LOC 741 841" (page
147)
lists main office B LOC provisioning.
Table 13
Main office B LOC provisioning for LOC 741 841
Create a CDP mapped to the LOC:
LD 87
REQ NEW
CUST 0
FEAT CDP
TYPE DSC
DSC 4030
FLEN 4
RLI 50
Create a CDP mapped to the LOC:
LD 87
Nortel Communication Server 1000
Main Office Configuration Guide for SRG 50
NN43001-307 02.02 Standard
Release 5.0 3 December 2007
Network using Uniform Dialing Plan 147
lists main office B DMI and RLI provisioning.
Create an RLI
LD 86
REQ new
CUST 0
FEAT rlb
RLI 50
ENTR 0
LTER no
ROUT 71
DMI 50

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srg50

Table of Contents