Enabling Behavior At A Zone; Nn43001-307 02.02 Standard - Nortel 1000 Configuration Manual

Nortel 1000 servers: user guide
Table of Contents

Advertisement

Command
ENL ZBR <zone> [ALL] [LOC][ESA][TIM][ALT] Enable features for the branch office zone. If you do
not input features, then all are enabled.
DIS ZBR [ALL] [LOC][ESA][TIM][ALT] Disable features for the branch office zone. If you do not
input features, then all are disabled.
The system responds with ok, if operation is successful.
LD 117 Change and Print Zone Alarm Suppression Time Interval
Command
CHG ZAST <zone> <Alarm Suppression Interval>
PRT ZAST <zone>
Sample printout:
#
10
11
12
Where # is the column header for zone number.
Element Manager maintenance
Enable branch office behavior for a zone
You can configure the Alternative Call Routing for NBWM feature while you
configure the zone's branch office behavior.
Procedure 13

Enabling behavior at a zone

Step
1
Copyright © 2005-2007, Nortel Networks
.
Description
Description
Change Suppression Time Interval for QoS alarms related
to Alternative Call Routing for NBWM feature for zone
specified. Time Interval is measured in seconds from the
time the last alarm was printed.
Default is 0. Range is 0 - 3600 seconds.
Print Suppression Time Interval for QoS alarms related
to Alternative Call Routing for NBWM feature for zone
specified. No entry for zone number results in printout for
all zones.
Action
From the navigator, click System > Maintenance. The Maintenance
web page appears. See
181).
Nortel Communication Server 1000
Main Office Configuration Guide for SRG 50

NN43001-307 02.02 Standard

Release 5.0 3 December 2007
Alarms Suppression Time
50
0
1000
Figure 74 "Maintenance web page" (page
Maintenance 185