Kohler KD103V20 Operation And Maintenance Manual page 173

Table of Contents

Advertisement

SPN
175
175
175
175
4811
4811
4811
4811
4811
4811
4811
3597
3597
3597
5571
5571
5571
516209
516209
5571
5571
516211
516212
516422
5571
516331
5571
516331
516215
516215
516215
516216
516217
516337
516215
516220
516221
KD103V20 33521030901_2_1 EN_US
2022-09
FMI
3
Oil temperature sensor - Short circuit to battery
4
Oil temperature sensor - Short circuit to ground
4
Oil temperature sensor - Short circuit to ground or open circuit
31
Oil temperature sensor - Supply voltage out of range
0
Piston cooling pressure 1 - Critical overpressure
1
Piston cooling pressure 1 - Critical underpressure
15
Piston cooling pressure 1 - Overpressure warning
17
Piston cooling pressure 1 - Underpressure warning
3
Piston cooling pressure sensor 1 - Short circuit to battery
4
Piston cooling pressure sensor 1 - Short circuit to ground or
open circuit
31
Piston cooling pressure sensor 1 - Supply voltage out of range
1
Power supply - Critical undervoltage
15
Power supply - Overvoltage warning
17
Power supply - Undervoltage warning
6
Pressure control valve - Critical high output current
0
Pressure control valve - Critical overcurrent
1
Pressure control valve - Critical undercurrent
15
Pressure control valve - Current remains above the set point
17
Pressure control valve - Current remains below the set point
11
Pressure control valve - Electrical error
5
Pressure control valve - Open circuit
11
Pressure control valve - PWM signal - High limit reached
11
Pressure control valve - PWM signal - Plausibility error
11
Pressure control valve - Short circuit load
3
Pressure control valve - Short circuit to battery high side
3
Pressure control valve - Short circuit to battery low side
4
Pressure control valve - Short circuit to ground high side
4
Pressure control valve - Short circuit to ground low side
6
Pressure control valve 2 - Critical high output current
0
Pressure control valve 2 - Critical overcurrent
1
Pressure control valve 2 - Critical undercurrent
11
Pressure control valve 2 - Current remains above the set point
11
Pressure control valve 2 - Current remains below the set point
11
Pressure control valve 2 - Electrical error
5
Pressure control valve 2 - Open circuit
11
Pressure control valve 2 - PWM signal - High limit reached
11
Pressure control valve 2 - PWM signal - Plausibility error
© 2022 by Kohler Co. All rights reserved.
Designation
Appendix
Error code
173