Error Code - Kohler KD103V20 Operation And Maintenance Manual

Table of Contents

Advertisement

8.2 Error code

Information
Error code list extracted from engine control unit software version 21.12.10 and dataset revision
9.
The following error code table is indicative. Refer to the technical data sheet of your engine for
the latest software version.
For further information, please contact your nearest authorized Kohler service representative.
Abbreviations:
– SPN - Suspect Parameter Number
– FMI - Failure Mode Identification
SPN
107
516101
516428
108
171
171
171
171
1176
1176
636
636
636
636
636
636
636
157
1239
157
516117
1075
516118
516121
516122
KD103V20 33521030901_2_1 EN_US
2022-09
FMI
11
Air filter - Blocked/clogged
31
Air filter pressure switch - Supply voltage out of range
31
Air pressure sensors - Plausibility error
31
Ambient pressure sensor - Supply voltage out of range
5
Ambient temperature sensor - Open circuit
3
Ambient temperature sensor - Short circuit to battery
4
Ambient temperature sensor - Short circuit to ground
31
Ambient temperature sensor - Supply voltage out of range
1
Boost pressure - Pressure too high
0
Boost pressure - Pressure too low
2
Camshaft position - Plausibility error
14
Camshaft position sensor - Ground error
5
Camshaft position sensor - Open circuit
3
Camshaft position sensor - Short circuit to battery
3
Camshaft position sensor - Short circuit to battery or open
circuit
4
Camshaft position sensor - Short circuit to ground
31
Camshaft position sensor - Supply voltage out of range
0
Common rail - Critical overpressure
2
Common rail - Leakage
15
Common rail - Overpressure warning
11
Common rail - PCV opened due to overpressure
2
Common rail - Plausibility error
11
Common rail - Plausibility error of VCV current
11
Common rail - Pressure remains above the set point
11
Common rail - Pressure remains below the set point
© 2022 by Kohler Co. All rights reserved.
Designation
Appendix
Error code
165

Advertisement

Table of Contents
loading