Siemens SIMOTION D4 Series Manual page 70

Hide thumbs Also See for SIMOTION D4 Series:
Table of Contents

Advertisement

Technical data of the D4x5-2
4.5 Interfaces and performance features
Address space for each
SINAMICS Integrated/CX32-2
(PROFIBUS Integrated)
Address space for each PROFINET
device
1)
Digital inputs
Table 4- 12
Data
Digital inputs
Galvanic isolation
Current consumption typ. at
signal level "1"
Input delay, typ. (hardware)
1)
2)
Digital inputs/outputs (parameterizable)
Table 4- 13
Data
Digital inputs/outputs
If used as an input
Galvanic isolation
Current consumption typ. at signal
level "1"
70
When PROFIBUS and PROFINET are used, the total address space applies
Digital inputs on SIMOTION D4x5-2
Rated value
For signal "1"
For signal "0"
2)
Reference potential is terminal M1 or M2
The digital inputs are protected against polarity reversal up to -30 V
Digital inputs/outputs on SIMOTION D4x5-2
Input voltage, rated value
Input voltage, for signal "1"
Input voltage, for signal "0"
512 bytes
1400 bytes
SIMOTION D445-2 DP/PN
12
24 VDC
15 ... 30 V
-3 ... +5 V
Yes, in groups of 6
1)
9 mA at 24 V
L -> H: 50 µs
H -> L: 150 µs
SIMOTION D445-2 DP/PN
16
Max. 16 as inputs of
measuring inputs
Max. 8 as outputs of output
cams / fast DOs
24 VDC
15 ... 30 V
-3 ... +5 V
2)
No
9 mA at 24 V
512 bytes
1400 bytes
SIMOTION D455-2 DP/PN
12
24 VDC
15 ... 30 V
-3 ... +5 V
Yes, in groups of 6
1)
9 mA at 24 V
L -> H: 50 µs
H -> L: 150 µs
SIMOTION D455-2 DP/PN
16
Max. 16 as inputs of
measuring inputs
Max. 8 as outputs of output
cams / fast DOs
24 VDC
15 ... 30 V
-3 ... +5 V
No
9 mA at 24 V
SIMOTION D4x5-2
Manual, 11/2010

Advertisement

Table of Contents
loading