SIMOTION D445-2 DP/PN and D455-2 DP/PN must be operated with a double fan/battery
module for heat dissipation. Without this module, the control units will not start up and
cannot be commissioned.
Information on how to install the double fan/battery module can be found in "Supplementary
system components", in Section Installing the fan/battery module (Page 80).
Note
With the D445-2 DP/PN and D455-2 DP/PN, the spacers can only be removed with the
"external air cooling" installation method. In this installation method, the cooling fins are
inserted through a cutout in the rear cabinet panel.
For further details, see the
Manual.
1.5

Nameplates

Side-mounted type plate
The following figure shows the information contained on the type plate mounted on the side
of the housing.
Figure 1-3
SIMOTION D4x5-2
Manual, 11/2010
CAUTION
SIMOTION D4x5-2
Type plate using the D445-2 as an example
Commissioning and Hardware Installation
Description
1.5 Nameplates
23