Interface characteristics
Table 3- 7
Characteristic
Connector type
Cable type
Maximum cable length
Minimum transmission
cycle
Autocrossing
Dust protection blanking
plugs for sealing unused
PROFINET ports
Interface assignments
Table 3- 8
Assignment of the ports X150 P1 to P3
View
Connectable devices
The following devices can be connected to the PROFINET IO interface:
● PG/PC programming devices (communication with SIMOTION SCOUT / STEP 7)
● SIMATIC HMI devices
● SIMATIC controllers with PROFINET interface
● Distributed I/O
● Drive units with PROFINET IO interface (standard devices)
SIMOTION D4x5-2
Manual, 11/2010
Ports X150 P1 to P3
Type
RJ45plus socket
PROFINET
100 m
0.25 ms
Yes
i.e. both crossed and uncrossed cables can be used
Five blanking plugs contained in the D4x5-2 scope of delivery
Blanking plugs (50 pcs) order number: 6SL3066-4CA00-0AA0
Pin
Name
1
TXP
2
TXN
3
RXP
4
-
5
-
6
RXN
7
-
8
-
3.4 PROFINET IO interface
Description
Transmit data +
Transmit data -
Receive data +
Reserved, do not use
Reserved, do not use
Receive data -
Reserved, do not use
Reserved, do not use
Interfaces
47

Advertisement

Table of Contents