Vent Line Termination Fitting - Polaris ACE 900 2017 Service Manual

Table of Contents

Advertisement

FUEL SYSTEM
1. Retain the fuel vent line to the chassis using an edge
t
clip with zip tie
.
2. Route the fuel vent line along the engine mount and
retain it with routing T-clip
3. Route the fuel vent line up the frame and retain the
vent line in the two hinge clips
4.22
r
.
e
.
4. Attach the vent line to the fitting in the frame

VENT LINE TERMINATION FITTING

This fitting should be inspected and tested using a Mity
Vac™ to ensure proper venting. Connect the Mity Vac to
the fitting and give it 5 pumps. The gauge should return
to 0 immediately or there is an obstruction.
NOTICE
If the vent line fitting is removed from the frame, it must
be replaced. The ears on the clip (arrows) will not hold
properly once it is removed.
9929422 R02 - 2017-2019 ACE 900 Service Manual
w
.
© Copyright Polaris Industries Inc.