Summary of Contents for GRASS VALLEY KALEIDO-RCP2

  • Page 1 KALEIDO-RCP2 Ethernet Remote Control Panel and KM Gateway Installation and Operation Manual M735-9902-105 2022-12-19 www.grassvalley.com...
  • Page 2 Valley USA, LLC, or one of its affiliates or subsidiaries. All other intellectual property rights are owned by GVBB Holdings SARL, Grass Valley USA, LLC, or one of its affiliates or subsidiaries. All third party intellectual property rights (including logos or icons) remain the property of their respective owners.
  • Page 3 Kaleido-RCP2 Installation and Operation Manual Document History See the Release Notes for more information about the features added to this product. Document Number Publication Date Notes M735-9902-105 2016-07-07 Initial release. M735-9902-105 2022-12-18 Update to new layout. Electrostatic Discharge (ESD) Protection...
  • Page 4 Grass Valley believes this environmental information to be correct but cannot guarantee its completeness or accuracy since it is based on data received from sources outside our company. All specifications are subject to change without notice.
  • Page 5 Kaleido-RCP2 Installation and Operation Manual Safety and EMC Standards This equipment complies with the following standards: Safety Standards Information Technology Equipment - Safety Part 1 EN60950-1: 2006 Safety of Information Technology Equipment Including Electrical Business Equipment. UL1419 (4 Edition) Standard for Safety – Professional Video and Audio equipment (UL file number E193966)
  • Page 6 EMC Performance of Cables and Connectors Grass Valley products are designed to meet or exceed the requirements of the appropriate European EMC standards. In order to achieve this performance in real installations it is essential to use cables and connectors with good EMC characteristics.
  • Page 7: Table Of Contents

    Updating the Kaleido-RCP2 Firmware ........
  • Page 8 Notices...
  • Page 9: Description

    • Note: Multi-function keyboards or numeric keypads that have a built-in USB hub do not work when connected to the Kaleido-RCP2. No other device than a mouse, a numeric keypad without USB hub, a keyboard without USB hub or special function keys can be connected to the Kaleido-RCP2.
  • Page 10: Usb Ports

    Kaleido-RCP2 2 USB Ports Two kinds of power sources are supported: • midspan power source injector into an existing Ethernet network, and • power sourcing Ethernet switch. Full redundancy is obtained with both supplies present at the same time. Ethernet connectivity is 10/100 Mbps.
  • Page 11: Layout Presets

    Kaleido-RCP2 Installation and Operation Manual Layout Presets The ten numbered keys laid out across the top of the panel are used to recall saved layouts to the monitor wall, and are also used to save layout. • Pressing and holding one of the preset buttons for 8 seconds will store the current layout to that button, allowing the user to easily return to it later.
  • Page 12: Keypad

    • Note: To reset the control panel, simultaneously press ESC, ENTER, and DEL. Configuration Before you can use your Kaleido-RCP2 to operate your Kaleido system, you must set up the Ethernet connection between the two devices. • Note: The Kaleido-RCP2 is powered through the RJ-45 Ethernet connector. There is no power ON/OFF button, so the device is ON when a powered Ethernet cable is connected.
  • Page 13: Ethernet Configuration

    IP address by a DHCP server. • If no DHCP server can be found, the Kaleido-RCP2 will default to its static IP address. • The time-out period before the Kaleido-RCP2 defaults to its static address is about 1 minute.
  • Page 14: Selecting A Room

    Kaleido-RCP2 Selecting a Room Kaleido-RCP2 Configuration menu summary Selecting a Room Use the Configuration menu to select the room you wish to access with your KaleidoRCP2—the ON AIR room, for example. Once you select the room, you can log on as a specific user, corresponding to one of the login positions that are available for this room only.
  • Page 15: Enabling Or Disabling Dhcp

    Kaleido-RCP2 Installation and Operation Manual Action LCD indication Other buttons Configuration Press and hold the ENTER Digit keys 2 (UP) and 8 button until the ESC button ROOM SELECTION (DOWN), and the lights up to access the ENTER and ESC Configuration menu, buttons are lit;...
  • Page 16: Setting An Ip Address, Subnet Mask And Gateway

    Setting an IP Address, Subnet Mask and Gateway The table below shows how to set a fixed IP address for a Kaleido-RCP2 unit. As an example, the IP address will be changed from 10.0.3.191 to 192.168.0.10. This task is performed by using the Configuration menu.
  • Page 17 Note: If you changed any of the network parameters (IP address, subnet mask or gateway), the Kaleido-RCP2 unit will reboot. When you change the DHCP mode, the device must be restarted for the new option to take effect. This is done automatically but only after you exit the Configuration menu. You can...
  • Page 18: Configuring Unicast Ip Addresses

    Kaleido systems in its own subnet. Notes: • To navigate the Kaleido-RCP2 menu, press the 2 key to move up, or the 8 key to move down. • There is no need to configure unicast IP addresses for Kaleido systems on the same subnet as the Kaleido-RCP2.
  • Page 19: Updating The Kaleido-Rcp2 Firmware

    Unicast IP addresses All three host IP address parameters set to 10.0.3.70 and disabled by default In addition, the current room and login position are erased from the Kaleido-RCP2 memory. Action LCD indication Other buttons Press and hold the ENTER...
  • Page 20: Firmware Selection (Step 1 Of 3)

    • A copy of the Kaleido-RCP2 firmware update file is on the PC. To prepare the firmware update: 1 Open the Kaleido-RCP2 Updater utility from a PC located on the same network as the Kaleido-RCP2 you wish to update. 2 Type the name of the firmware data file you wish to use to upgrade your RCP2 unit in the Firmware data file box.
  • Page 21: Firmware Update (Step 2 Of 3)

    Transferring the new firmware data to the main memory takes several minutes. Do not disconnect the Kaleido-RCP2 while it is updating its firmware, as this may result in a fatal error. In this event, it will be necessary to return the unit to Grass Valley to be reprogrammed.
  • Page 22: Verification (Step 3 Of 3)

    Verification (step 3 of 3) To verify that your RCP2 is updated properly: 1 On the Kaleido-RCP2, press and hold ENTER until the ESC button lights up, to access the Configuration menu. 2 Select the option DEVICE INFO, and then press ENTER.
  • Page 23 You may require a password to log on. A room is supposed to be already set through the configuration menu of the device. Here is a graphical summary of the login menu as it appears on the Kaleido-RCP2’s LCD display:...
  • Page 24: Enabling/Disabling The Kaleido-Rcp2 User Interface

    • All other keys on the Kaleido-RCP2 are disabled (LEDs off). • The LCD display is off. • Any peripherals (e.g. mouse, keyboard) connected to the Kaleido-RCP2's USB ports are also disabled. The purpose of the panel enable function is to lock the user interface of the remote, thus avoiding any accidental access to the Kaleido system.
  • Page 25: Specifications

    Kaleido-RCP2 Installation and Operation Manual Specifications Ethernet port Signal 100/10 BASE-T, (IEEE 802.3AF) Connector RJ-45 with LED and 48 V power USB ports Signal 1USB 2.0 (for low speed HID devices only, compatible with 1.1) Connector 2 USB host connectors (mouse and...
  • Page 26 Contact Us Grass Valley Technical Support For details of our Regional Customer Support Offices, please visit the Grass Valley website and navigate to Support. www.grassvalley.com/support/ Customers with a support contract should call their personalized number, which can be found in their contract, and be ready to provide their contract number and details.