Comtech EF Data HPOD Installation And Operation Manual page 91

C, x, ku-bandhigh power outdoor amplifier
Hide thumbs Also See for HPOD:
Table of Contents

Advertisement

Command
Parameter
Number of
(Instruction
Type
Arguments
& Qualifier)
Retrieve
N/A
117 bytes,
Alarm Status
alphanumeri
c
Retrieve
N/A
45 bytes,
Configuration
alphanumeri
Status
c
Serial-Based Remote Product Management
Description of Arguments
Query only.
Reports the Alarm status of the unit.
Example:
<1/RAS?'cr'
>0001/RAS='cr''lf'
P24VT=OK'cr'
P15VT=OK'cr'
P10V1=OK'cr'
P10V2=OK'cr'
P7V5T=OK'cr'
P5VLT=OK'cr'
N5VLT=OK'cr'
FAN#1=OK'cr'
FAN#2=OK'cr'
HSTMP=OK'cr'
SHTDN=OK'cr'
IICST=OK'cr'
FPOUT=OK'cr''lf'
Note: BUC=XX, and REF=XX will appear in the list if the BUC,
and reference oscillator are installed.
Query only.
Reports the configuration status of the unit.
Example:
<1/RCS?'cr'
>0001/RCS='cr''lf'
ATT=12.75'cr' (Attenuation in dB)
AMP=1'cr' (RF power amplifier state, 0=OFF, 1=ON)
MUT=1'cr' (RF mute state, 0=un-muted, 1=muted)
ONL=1'cr' (Online status for redundancy)
RED=1-1'cr' (Redundancy state and mode, states: 0=OFF,
1=ON, modes: 0=manual, 1=auto)
GOF=00.00'cr' (Gain Offset in dB)
AFR=1'cr''lf' (Auto Fault Recovery, 0=manual, 1=auto)
5–18
HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Query
Response to
(Instruction &
Command
Qualifier)
N/A
RAS?
N/A
RCS?
Revision 9
Response to
Query
RAS=x....x
(See
Description of
Arguments)
RCS=x....x
(See
Description of
Arguments)
MN/HPOD.IOM

Advertisement

Table of Contents
loading

Table of Contents