Comtech EF Data HPOD Installation And Operation Manual page 83

C, x, ku-bandhigh power outdoor amplifier
Hide thumbs Also See for HPOD:
Table of Contents

Advertisement

NOTE – Instruction Code Qualifiers, as defined in Sect. 5.4.2.5, are used in the command/query tables 'Response to Command'
columns:
=
Message OK
?
Received OK, but invalid arguments found
!
Invalid instruction
Command
Parameter
Number of
(Instruction
Type
Arguments
& Qualifier)
Auto Fault
AFR=
1 byte,
Recovery
value of 0,
1
RF Power
AMP=
1 byte,
Amplifier
value of 0, 1
State
Attenuation
ATT=
5 bytes,
numerical
Gain Offset
GOF=
5 bytes,
numerical
Serial-Based Remote Product Management
*
#
Description of Arguments
Command or Query.
Automatically mutes SSPA output in the event of detected fault.
If enabled, it causes the output to go active (un-mute) if all faults
are cleared. If disabled, output remains muted even if all faults
are cleared.
Example:
<1/AFR=1'cr'
>0001/AFR='cr''lf'
Command or Query.
Turn ON or OFF the RF power amplifiers, in the form x, where:
0 = Off
1 = On
Example: <1/AMP=1'cr'
Command or Query.
Set a valid attenuation level, in 0.25 dB increments, in the form
xx.xx.
Example: <1/ATT=12.25'cr'
Command or Query.
Set or query the adjusted attenuation level, in 0.25 dB
increments, in a 1:1 redundant system so power is equal
between the online and offline units when a switchover occurs, in
the form xx.xx.
Example: <1/GOF=02.00'cr'
5–10
HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Message OK, but not permitted in current mode
Message OK, but unit is not in Remote mode
Response to
Command
AFR=
AFR?
AFR*
AMP=
AMP?
AMP*
ATT=
ATT?
ATT*
GOF=
GOF?
GOF*
Revision 9
Query
Response to
(Instruction &
Query
Qualifier)
AFR?
AFR=x
(See
Description
of
Arguments)
AMP?
AMP=x
(See
Description of
Arguments)
ATT?
ATT=xx.xx
(See
Description of
Arguments)
GOF?
GOF =xx.xx
(See
Description of
Arguments)
MN/HPOD.IOM

Advertisement

Table of Contents
loading

Table of Contents