J6 | Com1' Connector; J8 | Input Sample' Connector; J9 | Output Sample' Connector; Table 2-6. 'J6 | Com1' Connector Pinout - Comtech EF Data HPOD Installation And Operation Manual

C, x, ku-bandhigh power outdoor amplifier
Hide thumbs Also See for HPOD:
Table of Contents

Advertisement

2.5.2 'J6 | COM1' Connector

The 'J6 | COM1' Discrete Control connector is the primary input for controlling and monitoring
the SSPA. It is a 19-pin circular connector, type MS3112E14-19S. The pinout specification is
shown in Table 2-6.
Mating connector: ITT: KPT06J14-19P or MS3116J14-19P.
Pin
A
B
C
D
E
F
G
H
J
K
L
M
N
P
R
S
T
U
V

2.5.3 'J8 | INPUT SAMPLE' Connector

The 'J8 | INPUT SAMPLE' port connector is a Type 'N' female. It provides a nominal –20 dB
sample of the input signal. A calibration label is provided near the connector that shows the actual
coupling values vs. frequency.

2.5.4 'J9 | OUTPUT SAMPLE' Connector

The 'J9 | OUTPUT SAMPLE' port connector is a Type 'N' female. It provides a nominal -40
dB sample of the output signal. A calibration label is provided near the connector that shows the
actual coupling values vs. frequency.
External Connectors and Pinouts

Table 2-6. 'J6 | COM1' Connector Pinout

Name
RS485_+RX
RS485_-RX
RS485_+TX
RS485_-TX
RS232_RD
Ethernet TX+
RS232_TD
Ethernet TX-
Aux_Out
Not for customer use
SumFLT_COM
SumFLT_NO
Open when faulted, else tied to Pin K.
SumFLT_NC
When faulted, tied to Pin K, else open.
GND
ONLINE_Status
Not for customer use
+24V
Not for customer use
When AUX=1, system is muted until this pin is pulled to
Mute Control
ground. At that time, the unit unmutes. See the AUX
remote command.
Minor_FLT_COM
Reserved for future use
Ethernet RX-
Ethernet RX+
2–8
HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Description
Revision 9
MN/HPOD.IOM

Advertisement