2.1.2 Circular Cable Connections

The circular connectors provided on the HPOD SSPA accommodate weatherproof outdoor
applications. The connector pairs (Figure 2-2) feature a sleeve lock configuration, with an array
of pins (male side) coupled to mating sockets (female side).
Connection Instructions – Engage all of the alignment and lock features
between the male connector (on the interconnection cable) and female socket.
To install the male connector into the female connector:
1) Engage the primary and secondary alignment tabs on the male connector
with the mating cutouts on the female socket.
2) Push the male connector into the female socket.
3) Turn the male connector sleeve clockwise until the sleeve lock cutouts
engage fully with the female socket tabs and you hear a "click" sound.
2.2

HPOD SSPA Cabling Connections

The HPOD SSPA external connectors (Figure 2-3) provide all necessary connections between
the unit and other equipment. Table 2-1 summarizes the connectors provided here, grouped
according to service function.
Additionally:
Detailed installation and operational information for using HPODs in 1:1 and 1:2
redundancy configurations is provided in Appendix A. REDUNDANCY SYSTEM
ASSEMBLY KITS and Appendix B. 1:1
OPERATION.
Information on the HPOD's M&C operability via serial remote commands and
queries is provided in CHAPTER 5. SERIAL-BASED REMOTE PRODUCT
MANAGEMENT.
External Connectors and Pinouts

Figure 2-2. Circular Connector Example

2–2
HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Feature
Description
1
Primary Alignment features
2
Secondary Alignment features
3
Sleeve Lock features
1:2 REDUNDANCY
AND
Revision 9
MN/HPOD.IOM