Download Print this page

Toshiba e-STUDIO5540C Service Manual page 1151

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO5540C:

Advertisement

Sub
05/08
Mode
Element
element
08
Setting
System
User
Mode
interface
08
Setting
System
User
Mode
interface
08
Setting
System
User
Mode
interface
08
Setting
System
General
Mode
08
Setting
System
User
Card reading device
Mode
interface
08
Setting
System
Forced
Mode
printing of
user name
08
Setting
System
Forced
Mode
printing of
user name
e-STUDIO5560C/6560C/6570C (Ver08)
Sub-
Item
Subitem
Code
code
8723
8724
8725
8726
8727
8728
8728
Default
Acceptable
Details
value
value
Pop-up display of
1
0-1
logging out of user
authentication and
department
management on the
control panel
Display setting of Edit
1
0-1
From Address button
for Scan to email
Display setting of
1
0-1
[USER FUNCTIONS]-
> CHANGE
LANGUAGE button
Job deletion on the
0
0-1
Job Status screen
Display of dedicated
0
0-1
screen for card
authentication
0
Display/Non-display
0
0-1
setting in TopAccess
1
Enable/Disable setting
0
0-1
of forced printing
215
RAM
Contents
SYS Sets whether the pop-up dialog of confirmation for
logging out is displayed when user or department logs
out by pressing [FUNCTION CLEAR] button twice or
pressing [ACCESS] button.
0: Logs out without displaying pop-up dialog
1: Displays pop-up dialog when logging out
SYS 0: Not displayed (From Address cannot be edited)
1: Displayed (From Address can be edited)
SYS Sets whether the [CHANGE LANGUAGE] button
accessed from [USER FUNCTIONS] button is displayed
or not. Use this code to prohibit users from changing
the language displayed on the control panel.
Administrators can change the language.
0: Not displayed
1: Displayed
SYS Use this code to enable the job deletion on the [Job
Status] screen. When "3: High level" is set for code 08-
8911, be sure to disable this setting.
0: Disabled
1: Enabled
SYS Switches whether the message to hold a card over the
card reader is displayed on the login screen when the
card authentication is enabled.
0: Disabled
1: Enabled
SYS 0: Disabled 1: Enabled
SYS Normally this setting is made in TopAccess.
0: Disabled 1: Enabled
Proce
Servic
dure
e UI
1
Yes
1
Yes
1
Yes
1
Yes
1
4
4

Advertisement