Technical data
9.24.1 Connection schedule SND40 (general)
The following illustration shows the connection schedule of a SND40 with one sensor as well as
with two sensors via a sensor switch box, together with the names of the required cables.
Fig. 63: Connection schedule with 1 sensor and with 2 sensors via sensor switch box
Pos: 102 /Schweis snah t/Kabel/KNS9 S @ 0\mod_1 127 2108 258 12_ 501.do cx @ 59 7 @ 2 @ 1
9.25

Sensor cable KNS9S

Usage: Connecting the combo sensors and the leakage flux sensors to the control unit.
The cable has a cable socket at the sensor side, and open end wires with wire-end ferrules at the
control unit side.
Versions of cable:
8
Fig. 64: KNS9S-G
Cable diameter:
Structure:
Bending radius:
Pos: 103 /Schweis snah t/Kabel/SKN S8 S @ 1\mod _12 186 2857 571 8_5 01.docx @ 726 3 @ 2 @ 1
118
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
KNS9S-G:
straight cable socket at sensor
side
Cable socket at sensor side: Harting HAN8
8.7 mm
2
8 × 0.5 mm
, LiYCY
54 mm: laid fixed, 130 mm: laid flexible
Note
For cables delivered starting Nov. 2014 following applies:
*A brown wire might be connected parallel together with a blue
wire. **Contact Nr. 8 might be connected with the cable shield.
This will not affect the proper functionality of the cable, the
sensor or the control unit.
Manual
KNS9S-W:
angled cable socket at sensor side
1:
2:
3:
6
7
8
5
1
2
4:
4
3
5:
6:
7:
**8: blank
B0059001 / Rev. 2.3
white
+12 V
green
-12 V
Brown
AGND
(+blue)*
yellow
Meas. signal 1
red
Meas. signal 2
grey
+coil
pink
-coil
shield