Operation
7.4
Setup – Test operation
The screen contains the same functions as shown in the measuring mode. However, the size of the
signalling is reduced in favour of the parameter list.
Fig. 39: Setup test operation
Pos: 53 /Sc hweis snaht/ Geräte/ SN D40/8 Bet rieb/Ei nrichte n X/Y-D iagno se @ 0\mod_ 112 860 3820 515 _50 1.docx @ 724 @ 2 @ 1
72
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Starts a positioning. (Signals see chapter
11.1 timing diagram test job with test job
PLC or test job KM)
Changes (on signal type "Eddy current") to
the mode
"Setup – X-Y-diagnosis".
Stores the settings and returns to the mode
"Setup – Program selection".
Starts measuring the turn speed. (Signals
see chapter 11.1 timing diagram speed
measurement with test job PLC or test job
KM)
Returns to the mode
"Setup – Program selection" without storing
the program parameters.
Manual
Prints out the signal visualization and
the program list.
Inserts the screen keyboard.
Enters the parameter.
Selects the program parameter from
the list.
Changes the program parameter.
B0059001 / Rev. 2.3