B0059001 / Rev. 2.3
6

Start-up

Pos: 44 /Sc hweis snaht/ Geräte/ SN D40/7 Inbet rieb nahme/Rundkö rpe r/Vo raus setzungen @ 0\mod_1 165 994 7452 03_ 501.d ocx @ 2 439 @ 2 @ 1
6.1

Prerequisites for Start-up

The following form helps to clarify whether the SND40 can be put into operation. This is the case if
all items can be checked out with YES.
Item
For sensor type EC9...,NS9.../NS12...:- Sensor with rubber buffers mounted and alignment
5
checked
All other sensor types: Sensor mounted, alignment and distance checked
Line-up facility for sensor is functional
Tube drive and tube feeder is functional
SND40 is mounted
Power supply for SND40 is connected and checked for function
Sensor cable is laid out, connected and checked
PLC interface is connected and checked for function (LEDs)
PLC is programmed (Setup and Auto operation) and checked for function
Tube drive is running slip-free, in Auto mode as well as in Setup mode
Suitable tubes in sufficient quantity ( >10) available for tests
Machine can be operated in Auto mode as well as in Setup mode at the day of Start-up
Operator and maintenance staff is ready for training
Pos: 45 /Sc hweis snaht/ Geräte/ SN D40/7 Inbet rieb nahme/Menüba um @ 0\mo d_11 272 1320 782 8_5 01.docx @ 55 8 @ 2 @ 1
5
When the sensor is contacting the material, all rollers are turning if the tube rotates
6
Marking for adjusting the sensor aligns with the weld seam. If the tube rotates, the distance remains
constant and smaller than the maximum stated in the data sheet
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Manual
6
Start-up
Yes
No
63