7 USER SCREEN CREATION FUNCTION
7 - 53
(e)
Precautions for using the CGI write parts
1)
Writing a value to a tag component with the CGI write part may change
the control of the programmable controller CPU. Ensure safety before
execution.
When CONFIRM = 1, the following confirmation screen appears.
2)
A user without the tag component write authority is not allowed to write
a value to a tag component with the CGI write part.
When a write is attempted, the following screen appears.
3)
When Device write disable request (YA) has been set to "Disable",
writing to a tag component with the CGI write part is not available.
When a write is attempted, the following screen appears.
4)
When "Data write" of the tag setting has been set to "Disable", writing
to a tag component with the CGI write part is not available. (Refer to
Section 6.3.3 for the tag setting.)
When a write is attempted, the following screen appears.
MELSEC-Q
7 - 53