Supplemental Coolant Additives For Fully Formulated Coolant; Maintenance Intervals - Detroit Diesel MBE 900 Operator's Manual

Hide thumbs Also See for MBE 900:
Table of Contents

Advertisement

HOT COOLANT
To avoid scalding from the
expulsion of hot coolant, never
remove the cooling system
pressure cap while the engine is
at operating temperature. Wear
adequate protective clothing
(face shield, rubber gloves,
apron, and boots). Remove the
cap slowly to relieve pressure.
If topping off is needed, add coolant
which is identical to the initial fill
coolant.
Supplemental Coolant Additives
for Fully Formulated Coolant —
The concentrations of some inhibitors
will gradually deplete during normal
engine operation. SCAs replenish
the protection for cooling system
components. The coolant must
be maintained with the proper
concentration of SCA. Detroit Diesel
Power Cool maintenance SCAs are
recommended.
The proper application of SCA will
provide:
□ pH control.
□ Restored inhibitor levels to prevent
corrosion.
□ Water softening to deter formation
of mineral deposits.
All information subject to change without notice. (Rev. 04/08)
DDC-SVC-MAN-0040 0704 Copyright © 2008 DETROIT DIESEL CORPORATION
MBE 900 ENGINE 2007 OPERATOR'S GUIDE
□ Cavitation protection to protect
wet sleeve cylinder liners.
Maintenance Intervals — Check
the nitrite concentration at the regular
intervals listed in Table 17 with a
Power Trac 3–Way Test Strip.
109