NOTICE:
Required specifications for water,
ethylene glycol, propylene glycol,
inhibitor packages and inhibitor
concentration are included in
this section. To avoid possible
engine damage from inadequate
or over concentrated coolant,
this information should be read
thoroughly before the coolant is
replaced.
Coolant Fill Option
Ethylene Glycol & Water + Corrosion
1
Inhibitors
Commercial Equivalent of DDC Power
Cool
Propylene Glycol & Water + Corrosion
1
Inhibitors
Ethylene Glycol & Water + OAT
Inhibitors
Water Only + Corrosion Inhibitors
Water Only + OAT Inhibitors
1
Preferred Coolant
2
Water-only coolant systems offer no freeze protection and should not
be used where ambient temperatures can fall to 0°.C (32° F).
Table 12
Initial Fill Coolant Options
EG & Water Plus SCA Inhibitor or
PG & Water Plus SCA Inhibitor —
These products are available as fully
formulated, phosphate-free, extended
service interval (ESI) coolants.
They are commercially available
from Detroit Diesel (recommended)
and other manufacturers as either
102
DDC-SVC-MAN-0040 0704 Copyright © 2008 DETROIT DIESEL CORPORATION
DDC Power Cool
Fully Formulated TMC RP-329 Type A
Antifreeze & Water
DDC Power Cool Plus
DDC Power Cool Plus
2
Water + DDC Power Cool 3000
2
Water + DDC Power Cool Plus 6000
a concentrated antifreeze or as a
pre-mixed antifreeze. The pre-mixed
antifreeze is ready for use, while the
concentrated coolant must be mixed
with water prior to use.