Sca Test Procedures - Detroit Diesel MBE 900 Operator's Manual

Hide thumbs Also See for MBE 900:
Table of Contents

Advertisement

NOTICE:
Failure to properly maintain coolant
with SCA can result in damage
to the cooling system and its
related components. Conversely,
over-concentration of SCA inhibitor
can result in poor heat transfer,
leading to engine damage.
Always maintain concentrations at
recommended levels. Do not use
traditional SCAs with OAT coolant.
Additional SCA must be added to the
coolant when it becomes depleted, as
indicated by a nitrite concentration
of 900 PPM or less. If the nitrite
concentration is greater than 900
PPM, do not add additional SCA. If
the nitrite concentration is above 3200
PPM, the system is over-inhibited and
should be partially drained and filled
with a 50/50 mix of water and EG or
PG.
In this case the EG or PG should
contain no inhibitors and should
conform to ASTM D4985. This
will dilute the over-concentrated
inhibitors.
All information subject to change without notice. (Rev. 04/08)
DDC-SVC-MAN-0040 0704 Copyright © 2008 DETROIT DIESEL CORPORATION
MBE 900 ENGINE 2007 OPERATOR'S GUIDE
NOTE:
In non-OAT systems, nitrite
concentration of 5000 PPM or
higher on an MBE 900 engine
suggests problematic additive
over-concentration. This condition
must be corrected by immediate
draining and flushing of the cooling
system. Refill the system with new fully
formulated or pre-charged coolant.
Check the nitrite concentration level at
the next maintenance interval with a
Power Trac 3–Way Test Strip.

SCA Test Procedures

Detroit Diesel Power Trac 3–Way
Coolant Test Strips should be
used to measure nitrite and glycol
concentrations. Part numbers
are in refer to section POWER
COOL ENGINE PRODUCTS.
Cavitation/corrosion is indicated
on the strip by the level of nitrite
concentration. Freeze/boil over
protection is determined by glycol
concentration.