Fh-L Series - Omron FZ5 Series Hardware Setup Manual

Vision sensor
Hide thumbs Also See for FZ5 Series:
Table of Contents

Advertisement

5-3-3

FH-L Series

Precautions for Safe Use
Power Supply and Wiring
• Keep the power supply wires as short as possible (Max.2 m).
• Use the specified wire size (AWG12 to 16).
• Recommended power source for FH-L series: OMRON S8VK-G24 or S8VS-24.
Ground
• The power supply circuit of the Sensor Controller is not insulated from the internal circuit.
• When the connected camera to Sensor Control comes packaged with a base, make sure to
mount with the base. Since the enclosure of the camera main body made of metals is
short-circuited with the internal circuit, the internal circuit might be short-circuited with FG if
no base is used, so that failures or malfunctions may be caused.
• It is short-circuited with FG of the customer device when installing it directly because the
case of the controller is connected with SG (0 V).
• Do not ground the plus (+) terminal when the FH-L series Sensor Controller is connected to
the FH-SC12/FH-SM12. Doing so may cause a short circuit of the internal circuit, resulting in
a malfunction.
Connect the FH-L series Sensor Controller to the FH-MT12 Touch panel monitor.
When you connect the Sensor Controller to the FH-MT12 via USB cable, do not ground the
positive terminal of 24 VDC power source. The internal circuit is possible to be given damage, it
can be cause the failure.
When connect the FH-L series Sensor Controller to the FH-SC12/FH-SM12: 12 megapix-
els camera
When you connect the Sensor Controller to the FH-SC12/FH-SM12, do not ground the positive
terminal of 24 VDC power source. The internal circuit is possible to be given damage, it can be
cause the failure.
Vision System FZ5 series Hardware Setup Manual (Z423)