Fh-1000/2000/3000/5000 Series; Fh-L Series; Fz5 Series; Fz5-L Series - Omron FZ5 Series Hardware Setup Manual

Vision sensor
Hide thumbs Also See for FZ5 Series:
Table of Contents

Advertisement

5-1-2

FH-1000/2000/3000/5000 Series

Precautions for Safe Use
• Re-confirm the followings before turning ON the power.
• Is the correct voltage and polarity of the power (ENC0_VDD/GND ENC1_VDD/GND)
which supplies to encoder cable (5 VDC)?
• Re-check the ground wire before turning ON the power.
5-1-3

FH-L Series

Precautions for Safe Use
• Confirm the following before turning ON.
• Is the voltage and polarity of the power source set correctly?
(24 VDC for positive terminal. 0 VDC for negative terminal.)
• Make sure to connect the earth (FG) only to the grounding terminal.
5-1-4

FZ5 Series

Precautions for Correct Use
RESET signal
Do not input RESET immediately after turning ON the power. If you want to use RESET input to
synchronize with the timing of startup, turn ON the RESET signal 15 seconds after turning ON
the power of the Sensor Controller.
5-1-5

FZ5-L Series

Precautions for Safe Use
Do not touch the fluorescent light or halogen lamp while in operation, or immediately after turn-
ing OFF the power.
Precautions for Correct Use
RESET signal
Do not input RESET immediately after turning ON the power. If you want to use RESET input to
synchronize with the timing of startup, turn ON the RESET signal 15 seconds after turning ON
the power of the Sensor Controller.
Vision System FZ5 series Hardware Setup Manual (Z423)
5 Setup and Wiring
5 - 5