PROFIBUS communication
B.9 GSD files
Example
The measured values sound velocity, temperature and ultrasonic amplitude are to be
transmitted. The following identifier combination should be set:
1. Free Place (for flow)
2. Short Identifier or long Identifier (for sound velocity)
3. Free Place (for net quantity)
4. Short Identifier or long Identifier (for ultrasonic amplitude)
An identifier is not required for the forward quantity and reverse quantity as the ultrasonic
amplitude is the last value to be transmitted.
Output data can only be transmitted and therefore the totalizer reset if the corresponding
"extended Identifier" (long) is used. The first byte of the output data always refers to the first
resettable totalizer.
If, for example, the "Resettable quantity forw. (long)" and "Resettable quantity rev. (long)"
identifiers for the forward and reverse quantity are set but the "Resettable quantity net (long)"
identifier is not set for the net quantity, i.e. the net quantity totalizer is the only one which cannot
be reset, the first byte of the output data will refer to the totalizer for the quantity forward.
B.9

GSD files

;*******************************************************************
;**
;**
;**
;**
;**
;*******************************************************************
#PROFIBUS_DP
GSD_Revision
Vendor_Name
Model_Name
Revision
Ident_Number
Protocol_Ident
Station_Type
FMS_supp
Hardware_Release
Software_Release
Bitmap_Device
31.25_supp
45.45_supp
93.75_supp
98
GSD Datei für SITRANS FUS060, SIEMENS AG
MLFB: 7ME3050-*AB20-1BA*
Stand: 26.08.2015
Si028159.GSD
= 4
= "SIEMENS AG"
= "SITRANS FUS060V4"
= "04"
= 0x8159
= 0
= 0
= 0
= "September 2015"
= "4.00.00"
= "SIE8159n"
= 1
= 1
= 1
SITRANS FUS060 with PROFIBUS PA