GEM-RP2ASe2/GEM-K2AS Keypad Easy Program Menu
Enter the Dealer Security Code (default = 456789) for a new panel or enter your custom Dealer Program Code if
GEMINI
SYSTEM ARMED
programmed. Press the PRIOR/NO button repeatedly until "TURNON/PROG" is displayed. NOTE: If you pass "TURNON/PROG",
ENT A1
ENT A1
01/01/97 12:00AM
you can scroll back by pressing
NEXT/YES
A
1 2
3
E
D
PRIOR/NO
B
4
5 6
F
following steps, press
AREA
C
7 8 9 0
G
COMPUTERIZED SECURITY SYSTEM
R
backwards,
Ent A1
#ZnXX
(Direct Entry)
system, enter the total number of zones required for Areas 1 & 2. The Direct Address Program Mode can then be used to remove zones from
Area 1 and place them in Area 2. See Zone Options. If Programming a Wireless-Only system, or using Wireless-Only on Zones 9-32, enter
the total number of zones in system. Enter the transmitter points in the RF Transmitter section of the Easy Menu Driven Programming Mode.
Zn Dbl
Enabl?
Y/N
(Press YES or NO)
Ent Fr
Zn#XX
(Direct Entry)
Ent2WF
Zn#XX
(Direct Entry)
Report
all Zn
Y/N
(Press YES or NO)
EntEE1
Zn#XX
(Direct Entry)
X
GEM-P1632 Programming Instructions
. Press the NEXT/YES button to enter the Dealer Program Mode. In each of the
B
to jump to the next screen, the NEXT/YES button to go forwards, the PRIOR/NO button to go
R
U
to save and
twice to exit at any time.
C
Total Number of Zones in Area 1 (Appears for New Panel Only)
Directly enter the total number of zones to be programmed for Area 1. Valid entries are from 01 to 32. Directly
enter the total number of zones, including leading zeros. Use number buttons
Press
for a zero. The system is based on groups of 4 zones each (after the first 8 zones), and will
0
automatically round up to the next group of 4. For example, if you enter 18, it will automatically convert this to 20
U
zones. Press
to save. Press the NEXT/YES button to proceed. NOTE: If you are programming a 2 Area
Panel Zone Doubling (Appears for New Panel Only)
If the total number of zones in Area 1 entered was 16 or greater, press the NEXT/YES button to effectively
double the capacity of the control panel's hard wired zones from 8 to 16. The 16 zones will remain EOL
terminated zones, but will be designated for Normally Closed devices only. The terminal for Zone 1 will now
support Zones 1 and 9 with the use of the supplied EZ Zone Doubling
Wiring Diagram and Installation Instructions). If Panel Zone doubling is not desired, press the PRIOR/NO
button.
Fire Zones in Area 1 (Appears for New Panel Only)
Enter the zone number of any zones which are to be used as Fire Zones (both 2-wire, 4-wire or wireless). Valid
entries are from 01 to 32. Directly enter each zone number, including leading zeros, and press
then repeat for any additional zone(s). Press NEXT/YES button to proceed.
NOTE: If you are programming a 2 Area system, enter all the zone numbers required for Areas 1 & 2. The
Direct Address Program Mode can then be used to remove zones from Area 1 and place them in Area 2. See
Zone Options.
2-Wire Fire Zones in Area 1 (Appears for New Panel Only)
Enter the zone numbers of any Fire Zones (from previous question) which are to be used with 2-wire smoke
detectors. The only valid entries are 07 and 08. Directly enter each zone number, including leading zeros.
U
Press
to save, and then repeat for any additional zone(s). NOTE: Only zones which have been designated
as Fire Zones in the prior question may be programmed as 2 Wire Fire zones. Press the NEXT/YES button to
proceed. NOTE: JP3 must be set to "2-WF" position for 2-wire fire zones (refer to Installation Instructions).
Local or Central Station Reporting System (Appears for New Panel Only)
Press the NEXT/YES button for all zones to report; press the PRIOR/NO button for no zones to report (LOCAL
SYSTEM).
Exit/Entry Zones in Area 1 (Appears for New Panel Only)
Directly enter the zone number of any zones which are to be used as Exit/Entry zones. Valid entries are from 01
to 32. Directly enter each zone number, including leading zeros. Use number buttons
NOTE: Press the
button for a zero. Press
0
the NEXT/YES button to proceed.
NOTE: Chime will automatically be programmed for all E/E zones. If you are programming a multiple area
system, enter all exit/entry zone numbers required for Areas 1 & 2. The Direct Address Program Mode can then
be used to remove zone from Area 1 and place them in Area 2. See Zone Options.