Direct Address Programming Example - NAPCO GEMINI GEM-P1632 Programming Instructions Manual

Control panel/communicator
Table of Contents

Advertisement

Page 22
B. GEM-K3DGTL/GEM-RP3DGTL Keypads
To access Direct Address Program
Mode, press C in the Easy
Menu Mode.
1. Press R.
2. Enter the 4 digit Address location
directly using number buttons
(0-9).
3. Enter the 2 digit data directly
using number buttons (0-9).
U
4. Press
to save.
To exit, press C.
NOTE: "A" =
G 0
"F" =
. Press
G 5
Example: Direct Address Programming
Program Zones 6, 7 and 8 as Exit/Entry Follower Zones.
DETERMINE THE DATA ENTRIES
1. Referring to ZONE FEATURES in the Programming Worksheets that follow, Exit/Entry Follower for Zones 5
through 8 are located at address 0916, left digit. Circle
2. Add the data values for Zones 6, 7 and 8: 2+4+8=14. From Tables 1 and 2, "14" (E) is entered as press
. The right digit (for Zones 1 through 4, none of which are Exit/Entry Follower Zones) is entered as
G4
a blank (•).
ZONE OPTION
EXIT/ENTRY FOLLOWER
PROGRAM THE DATA ENTRIES
1. Enter the panel's Dealer Security Code, then press
2. Answer NO (
F
NOTE: If you pass "ACTIVATE PROGRAM", scroll backward using
3. Press
to enter the Address Program Mode. Address "0000" will display.
C
4. Press
0916
will advance to the data field.
5. Press
G 4
U
6. Press
to save. Address 0916 is now programmed with "E •".
7. Enter another 4-digit address to continue programming or press
X
GEM-P1632 Programming Instructions
GEMINI
COMPUTERIZED SECURITY SYSTEM
; "B" =
; "C" =
G 1
for a zero or to clear.
0
ZONES
LEFT DATA VALUES
SUM = 14 (CIRCLE
ZN08
ZN07
ZN06
) to all questions until "ACTIVATE PROGRAM Y/N" is displayed; then press the NEXT/YES button.
to access Address 0916. The data for both digits will display and the cursor
to enter an "E" in the left digit and press
SYSTEM ARMED
3C
01/01/97 12:00AM
INT ERIOR
BYPASS
A
1 2
3
B
4
5 6
C
7 8 9 0
; "D" =
G 2
the data values for Zones 5–8.
ADDRESS 0916
)
L
ADDR
R
ZN05
E
BLANK (•)
1
0916
ENTER DATA
.
R
.
B
to enter a blank (•) in the right digit.
0
to exit and resume normal keypad operation.
C
Flashing
ENT A1
FIRE/T BL
SYS TBL
CHIME
NEXT/YES
E
D
PRIOR/NO
F
AREA
G
R
; "E" =
G 3
G 4
ZONES
RIGHT DATA VALUES
ZN04
ZN03
ZN02
ZN01
8
4
2
L
NAPCO Security Systems
WI1148B 10/06
Press here to
Select NEXT/
PRIOR address
;
1

Advertisement

Table of Contents
loading