Enable Telco Line Fault Test; Enable Burg Output Chirp On Keyfob; Enable; Number Of Keypads In Area 1 - NAPCO GEMINI GEM-P1632 Programming Instructions Manual

Control panel/communicator
Table of Contents

Advertisement

Page 8
EntAUB
Zn#XX
(Direct Entry)
EnNEOL
Y/N
(Press YES or NO)
Telco
Ln Fit
Y/N
(Press YES or NO)
KF Out
Chirp
Y/N
(Press YES or NO)

Enable

CP01?
Y/N
(Press YES or NO)
Ent A1
#KP 01
(Direct Entry)
Phone#
_ _ _ _ _ _
_ _ _ _ _ _
(Direct Entry)
X
GEM-P1632 Programming Instructions
Auto Bypass Re-entry Zones (New Program Only) (Not evaluated by UL)
Enter the zone numbers of zones to be Auto Bypass Re-entry zones.
Valid entries are from 01 to 32. Directly enter each zone number, including leading zeros.
U
Press
to save and then repeat for any additional zone(s), press the NEXT/YES button to proceed.
Auto Bypass Re-entry Zones allow the system to be armed with the zone faulted but come back into
the system (armed) when the zone is subsequently secured.
Enable No EOLR Zones (New Program Only)
Press the NEXT/YES button to program all zones except 24 Hr & fire zones for No End Of Line Resis-
tor. Press the PRIOR/NO button to continue. NOTE: Do not program this feature for UL Installations.
Enable Telco Line Fault Test? (New Program Only)
Press the NEXT/YES button to enable Telco Line Fault Test.
Press the PRIOR/NO button to continue.
NOTE: If enabled, a Telco Line Fault Test Delay of 60 seconds will automatically be programmed.
Enable Burg Output Chirp on KeyFob? (New Program Only)
Press the NEXT/YES button to enable Burg Output Chirp on KeyFob Arm / Disarm.
Press the PRIOR/NO button to continue.
NOTE: The Burg Output will chirp once on Keyfob Arm and twice on Keyfob Disarm.
Enable SIA CP01? (New Program Only)
Press the NEXT/YES button to enable.
Press the PRIOR/NO button to continue.
The SIA CP-01 Features are designed to reduce the incidence of false alarms. See WI808, "Installer Pro-
gramming Quick Reference Chart SIA False Alarm Reduction" and "GEM-P1632 Factory Default Descrip-
tion" for more information. NOTE: Do not enable unless reporting, otherwise system trouble Fail to
Communicate may occur.

Number of Keypads in Area 1

Directly enter the total number of Keypads to be installed in Area 1. Valid entries are from 01 to 07. Directly
enter the number of keypads, including leading zeros. Use number buttons
Press
for a zero. Press
0
keypads can only be assigned in Direct Address Programming. See Keypad Options.
Central Station Receiver 1 Telephone Number
Using number buttons, enter telephone number of up to 16 digits including prefix letters, if necessary, for
receiver 1. Use number buttons
zero and
through
G 1
Tone Detection = "E". Pressing
YES button to proceed.
NOTE:
Central Station Receiver 2 and 3 Telephone Numbers can only be entered in Direct Address
Programming. See CS Receiver Options.
U
to save. Press the NEXT/YES button to proceed. NOTE: Area 2, 3 or 4
through
for digits 1–9; press the
1
9
for letters B–F, respectively. NOTE: Pre-Dial Delay = "D"; Dial-
G 5
will produce a blank space (•). Press
0
WI1148B 10/06
through
1
9
G 0
U
to save. Press the NEXT/
L
NAPCO Security Systems
. NOTE:
buttons for a