Page 20
DIRECT ADDRESS PROGRAM MODE
This is an extension of the Dealer Program Mode. This method of programming is used in conjunction with the Keypad
Programming Worksheets that follow. Refer to these worksheets to identify the 4-digit location (address) of the feature
to be programmed. An illustrative example is provided on the next page.
DATA ENTRY
ADDRESS
LOCATIONS
LOCATIONS
LEFT DIGIT
3
0000
0000
HEXADECIMAL DATA:
•
TO
BLANK (•) = No Options
2287
•
1 to 9 = Entries 1 to 9
•
0 = Entry of 10
•
B to F = Entries 11 to 15
ACCESSING DIRECT ADDRESS PROGRAM MODE
1. Press
2. Press the PRIOR/NO (Q) button until:
3. Press the NEXT/YES (P) button to enter Dealer Program Mode.
4. Press C to exit Easy Menu Driven Program Mode & enter
X
GEM-P1632 Programming Instructions
RIGHT DIGIT
C
EEEEEE
Dealer Security Code
(Default is 456789)
"TURNON PROG Y/N" (GEM-RP2ASe2/GEM-K2AS)
--or--
"17" (GEM-RP3DGTL/GEM-K3DGTL or GEM-RP4RFC/GEM-
K4RF) appears on the keypad display.
(The panel and keypad version appears briefly on the keypad display).
Direct Address Program Mode.
(For keypad display examples when in Program Mode, see next page).
KEYPAD PROGRAMMING OVERVIEW
Direct Address Programming allows you to go directly to the
address locations and change the data entries to customize your
control panel options. Whereas the Easy Menu Program Mode is a
simple quick start guide with limited options, the Direct Address
Program Mode is more flexible allowing you to change all the
options.
It consists of multiple address locations with two data entry
locations each (left and right) as shown in the adjacent diagram.
R
WI1148B 10/06
L