Procedure 7.5 - Replacing a Crankarm Assembly

Warning: Care must be taken when work is being performed in the area of the stairarms. Pinch
points exist between the stairarm and ramp and between the stairarm and crankarm, when the
rear covers are removed.
Procedure
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in Sec-
tion One, Things You Should Know.
1.
Remove the access panel, top, left and right cover sections as described in Procedure 7.1.
2.
Remove the left and/or right stairarm assembly as described in Procedure 7.14.
Note:
Notice the position of the two crank arms. When the crankarms are replaced, they must be posi-
tioned so that they are 180 degrees opposing.
3.
Remove the bolt that secures the crankarm to the input pulley shaft. It will be necessary to
use a Pitman arm puller or 4" to 6"gear puller to remove the crankarm. Do not use a hammer
or mallet to remove the crankarm.
4.
If you are removing both crank arm assemblies, repeat steps 2 and 3 for the second
crankarm assembly.
Diagram 7.5 - Crankarm
Crankarm
Bolt