Precor C524 Service Manual

Elliptical fitness crosstrainer
Hide thumbs Also See for C524:
Table of Contents

Advertisement

Quick Links

C524, C524i Elliptical Fitness Crosstrainer
C524, C524i Elliptical Fitness Crosstrainer
Warning: This service manual is for use by Precor trained service providers only.
If you are not a Precor Trained Servicer, you must not attempt to service any Precor Product;
Call your dealer for service.
This document contains information required to perform the majority of troubleshooting, and
replacement procedures required to repair and maintain this product.
This document contains general product information, software diagnostic procedures (when
available), preventative maintenance procedures, inspection and adjustment procedures,
troubleshooting procedures, replacement procedures and electrical block and wiring diagrams.
To move directly to a procedure, click the appropriate procedure in the bookmark section to the
left of this page. You may "drag" the separator bar between this page and the bookmark section
to change the size of the page being viewed.
© 2004 Precor Incorporated
Unauthorized Reproduction and Distribution Prohibited By Law
20039-131
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Precor C524

  • Page 1 C524, C524i Elliptical Fitness Crosstrainer Warning: This service manual is for use by Precor trained service providers only. If you are not a Precor Trained Servicer, you must not attempt to service any Precor Product; Call your dealer for service.
  • Page 2: Section One - Things You Should Know

    C524, C524i Elliptical Fitness Crosstrainer Section One - Things You Should Know Right, Left, Front, and Back Conventions In this manual, right, left, front, and back are from the perspective of a user standing on the EFX, facing the display enclosure.
  • Page 3 C524, C524i Elliptical Fitness Crosstrainer • Removing the covers exposes high voltage components and potentially dangerous machinery. Exercise extreme caution when you perform maintenance procedures with the cover(s) removed. • During service operations you will be very close to moving machinery and voltage bearing components.
  • Page 4: General Information

    C524, C524i Elliptical Fitness Crosstrainer General Information For the latest exploded view, part number and part pricing information, visit the Precor dealer website at “www.precor.com/connection”. Tools Required Multimeter Allen wrench set Anti-static kit Screwdriver set 4” - 6” gear puller 7/16”...
  • Page 5: Section Two - Preventive Maintenance

    Dry with a clean towel. A 30:1 solution of Simple Green and water is the only cleaning solution that has been tested and approved for use on the C524 or C524i ramps. Use of any other cleaner, may cause degradation of the ramp anodizing and void the ramp warranty.
  • Page 6: Quarterly Maintenance

    • Check speed sensor function (is the stride rate displayed when the unit is in operation?). If not, see Procedure 6.3 (C524) or Procedure 6.4 (C524i). • Visually inspect the drive belts for cracks, fraying or excessive wear. •...
  • Page 7: Procedure 3.1 - Software Access Codes

    The allowable delay between key presses is short. If too much time is taken between key presses the access procedure will be aborted. If the access is aborted, it will be necessary to start over from the beginning. See Diagram 3.1. On the C524 display key #1 is the CROSS RAMP key and key #4 is the RESET key.
  • Page 8: Procedure 3.2 - Accessing The Diagnostic Program

    Procedure Start pedalling and continue to pedal as you perform step 2. With the PRECOR banner scrolling, press keys RESET,5,1,7,6,5,7,6,1., sequentially. The message HARDWARE VALIDATION will be displayed for a few seconds. The message DISPLAY TEST will be displayed followed by every LED on the display being illuminated.
  • Page 9 C524, C524i Elliptical Fitness Crosstrainer 10. The message BRAKE TEST will be displayed followed the resistance level and brake level readings. This test allows you to test the brake (resistance) at each resistance level. Press the ENTER key to exit the diagnostics program.
  • Page 10: Procedure 3.3 - Displaying The Odometer

    Procedure Start pedalling and continue to pedal as you perform step 2. With the PRECOR banner scrolling, press keys RESET,6,5, sequentially. The message INFORMATION DISPLAY will be displayed for a few seconds. The message ODOMETER will be displayed followed by the total number of strides accumulated.
  • Page 11: Procedure 3.4 - Club Settings

    Procedure 3.4 - Club Settings Start pedalling and continue to pedal as you perform step 2. With the PRECOR banner scrolling, press keys RESET,5,6,5,1,5,6,5, sequentially. The message SET CLUB PARAMETERS will be displayed for a few seconds. The message SELECT LANGUAGE will be displayed followed by the currently selected keys to select the language preference.
  • Page 12: Procedure 3.5 - Documenting Software Problems

    If you isolated the problem to either the PROM, upper PCA, or lower PCA, include the information you recorded with the malfunctioning PROM or PCA when you ship it to Precor. When a problem occurs, record the following information: •...
  • Page 13 Start striding on the EFX or plug the optional external power supply (when available) into the EFX and the AC outlet. At the PRECOR banner, press QUICK START. Select Resistance Level 1 and press ENTER. Operate the EFX for 4–5 minutes. As you operate the EFX, concentrate on the operating sounds made by the unit.
  • Page 14: Procedure 5.1 - Measuring The Resistance Of A Generator (C524, Only)

    C524, C524i Elliptical Fitness Crosstrainer Procedure 5.1 - Measuring the Resistance of a Generator (C524, only) Caution Remove power from the EFX before you measure generator resistance. Procedure Remove the rear cover and disconnect the red battery lead from terminal M6 of the lower PCA.
  • Page 15: Procedure 5.2 - Measuring The Resistance Of A Generator (C524I, Only)

    C524, C524i Elliptical Fitness Crosstrainer Procedure 5.2 - Measuring the Resistance of a Generator (C524i, only) Caution Remove power from the EFX before you measure magnet resistance. Procedure Remove the rear cover and disconnect the red battery lead from terminal M6 of the lower PCA.
  • Page 16 C524, C524i Elliptical Fitness Crosstrainer Replace the generator per Procedure 7.17. Reconnect the intermediate cable removed in step 5 to the replacement generator and the lower PCA. Reconnect the red battery lead to terminal M6 of the lower PCA. Page 16...
  • Page 17: Procedure 5.3 - Inspecting And Adjusting Belt Tension

    C524, C524i Elliptical Fitness Crosstrainer Procedure 5.3 - Inspecting and Adjusting Belt Tension Procedure Remove the rear cover and disconnect the red battery lead from terminal M6 of the lower PCA. If you are only inspecting the generator belt tension, skip to step 7.
  • Page 18 C524, C524i Elliptical Fitness Crosstrainer both bolts equal amounts. When the adjustment is complete the step up pulley shaft must remain perpendicular to the frame and drive belt. Turning the adjustment bolts clockwise will increase belt tension, turning the adjustment bolts counter-clockwise will decrease belt tension.
  • Page 19 C524, C524i Elliptical Fitness Crosstrainer Reconnect the red battery lead to terminal M6 of the lower PCA. Page 19...
  • Page 20: Procedure 5.4 - Calibrating The Lift Motor

    C524, C524i Elliptical Fitness Crosstrainer Procedure 5.4 - Calibrating the Lift Motor Remove both front covers. Remove the four screws that fasten the lift motor yoke into the ramp. Carefully, slide the lift motor yoke out of the ramp and lower the ramp until it is resting on the frame.
  • Page 21: Procedure 6.1 - Troubleshooting The Lower And Upper Interconnect Cable

    If you are troubleshooting an error 30, 31 or 32 continue with step 3, otherwise see Procedure 6.3 (C524) or Procedure 6.4 (C524i). 10. Pry the end cap out of the front of the frame base tube (See Diagram 6.1).
  • Page 22 C524, C524i Elliptical Fitness Crosstrainer 13. Remove the rear cover. Disconnect the lower interconnect cable from the lower PCA and the mid-point connector. Substitute a known good interconnect cable from the lower PCA to the mid-point connector. It is not necessary to route the test interconnect cable through the frame tube, for convenience route it externally.
  • Page 23: Procedure 6.2 - Troubleshooting The Keypad And Upper Pca

    C524, C524i Elliptical Fitness Crosstrainer Procedure 6.2 - Troubleshooting the Keypad and Upper PCA If the function keys on the electronic console are unresponsive, the problem may be either the upper PCA or keypad. The keys on this unit are touch sensitive keys. It is necessary to use the keypad diagnostics to troubleshoot the key functions.
  • Page 24 C524, C524i Elliptical Fitness Crosstrainer Set the on/off switch in the “on” position. If an Error 5 “key depressed” message is immediately displayed when the EFX is powered up, replace the upper PCA. If a “key depressed” message is not displayed when the EFX is powered up, replace the display housing front panel.
  • Page 25: Procedure 6.3 - Upper Display Does Not Illuminate (C524, Only)

    If the AC outlet voltage is significantly low or 0 Vdc, the AC system must be inspected by an electrician. Troubleshoot the generator per Procedure 6.5 (C524) or Procedure 6.6 (C524i). If the generator was found to be good, the problem will be in either the lower PCA, upper PCA or the upper to lower PCA interconnect cables.
  • Page 26 C524, C524i Elliptical Fitness Crosstrainer Diagram 6.3 - Partial View of Lower PCA J2 Connector TP20 F1 Fuse 10. Troubleshoot the upper to lower PCA interconnect cables per Procedure 6.1. 11. If the upper to lower interconnect cables are found to be good, replace the upper PCA.
  • Page 27: Procedure 6.4 - Upper Display Does Not Illuminate (C524I, Only)

    C524, C524i Elliptical Fitness Crosstrainer Procedure 6.4 - Upper Display does not Illuminate (C524i, only) Because this is self powered unit, the display will not illuminate until it is used or the optional external power supply is equipped. If the optional external power supply is equipped, the display should be constantly illuminated.
  • Page 28 C524, C524i Elliptical Fitness Crosstrainer Diagram 6.4 - Partial View of Lower PCA DGND, TP14 PROM +5D, TP13 DS1 LED J2 Connector 10. Troubleshoot the upper to lower PCA interconnect cables per Procedure 6.1. 11. If the upper to lower interconnect cables are found to be good, replace the upper PCA.
  • Page 29: Procedure 6.5 - Troubleshooting The Generator (C524, Only)

    Because of the danger of working on the unit while it is in motion using the optional external power supply is strongly recommended. Perform the generator resistance test per Procedure 5.1 (C524) or Procedure 5.2 (C524i). If any of the resistance measurements are significantly high or significantly low, replace the generator.
  • Page 30: Procedure 6.6 - Troubleshooting The Generator (C524I, Only)

    C524, C524i Elliptical Fitness Crosstrainer Procedure 6.6 - Troubleshooting the Generator (C524i, only) The generator performs three functions in the EFX. First, by controlling the amount of electrical load applied to the generator, the user’s pedalling resistance is controlled. Second, the generator is used to charge the EFX’s internal battery.
  • Page 31: Procedure 6.7 - Troubleshooting The Lift Motor

    C524, C524i Elliptical Fitness Crosstrainer Procedure 6.7 - Troubleshooting the LIft Motor The lift motor is a 12 Vdc motor with an internally driven 1 KΩ potentiometer used to track ramp position. Because the lift motor is a DC motor, lift motor direction is controlled by the polarity of the DC voltage applied to the lift motor.
  • Page 32 C524, C524i Elliptical Fitness Crosstrainer Remove both front covers. Enter the diagnostic program, if necessary, per Procedure 3.2. Using the diagnostic program allows to test the lift system without continuously pedalling the unit. Connect a DC volt meter to the lift motor cable as follows: voltmeter common lead to terminal 2 (brown wire) and voltmeter “hot”...
  • Page 33: Procedure 7.1 - Replacing The Display Enclosure Or Upper Pca

    Procedure 7.1 - Replacing the Display Enclosure or Upper PCA Anti-static kits (part number 20024-101) can be ordered from Precor. The keyboard is part of the display housing front panel. If the keyboard is not functioning properly, replace the display housing front panel.
  • Page 34 C524, C524i Elliptical Fitness Crosstrainer Diagram 7.1 - Display Housing Front Panel, Rear View Upper PCA J5 Connector Keypad Connector Keypad Position the upper PCA at its mounting location on the display housing front panel (refer to Diagram 7.1). Replace and tighten the upper PCA mounting screws.
  • Page 35: Procedure 7.2 - Replacing The Lower Pca (C524, Only)

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.2 - Replacing the Lower PCA (C524, only) Removing the Lower PCA Remove the rear cover and disconnect the red battery lead from terminal M6 of the lower PCA. WARNING Before continuing with this procedure, review the Warning and Caution statements listed in Section One, Things You Should Know.
  • Page 36 C524, C524i Elliptical Fitness Crosstrainer Replacing the Lower PCA Position the replacement lower PCA at its mounting position and fasten the lower PCA with the four screws removed in step 5. Reconnect the lower PCA cables and wiring as follows. Connect the interconnect cable to connector J2.
  • Page 37: Procedure 7.3 - Replacing The Lower Pca (C524I, Only)

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.3 - Replacing the Lower PCA (C524i, only) Removing the Lower PCA Remove the rear cover and disconnect the red battery lead from terminal M6 of the lower PCA. WARNING Before continuing with this procedure, review the Warning and Caution statements listed in Section One, Things You Should Know.
  • Page 38 C524, C524i Elliptical Fitness Crosstrainer Replacing the Lower PCA Position the replacement lower PCA at its mounting position and fasten the lower PCA with the four screws removed in step 5. Reconnect the lower PCA cables and wiring as follows. Connect the interconnect cable to connector J2.
  • Page 39 C524, C524i Elliptical Fitness Crosstrainer Procedure 7.4 - Replacing the Upper and/or Lower Interconnect Cables Procedure Note: Before you install a new interconnect cable, ensure that the interconnect cable is defective. Refer to Procedure 6.1. Remove the rear cover and disconnect the red battery lead from terminal M6 of the lower PCA.
  • Page 40 C524, C524i Elliptical Fitness Crosstrainer Securely tape one end of the replacement lower interconnect cable to the lower PCA end of the existing lower interconnect cable. Carefully draw the existing lower interconnect cable out of the front of the frame as you carefully feed the replacement cable into the access hole near the lower PCA.
  • Page 41: Procedure 7.5 - Replacing A Crankarm Assembly

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.5 - Replacing a Crankarm Assembly Removing a Crankarm Assembly WARNING Before continuing with this procedure, review the Warning and Caution statements listed in Section One, Things You Should Know. It is only necessary to remove the right or left side of the rear cover to access the crankarm being replaced.
  • Page 42 C524, C524i Elliptical Fitness Crosstrainer Replacing a Crank Arm Assembly Clean the crankarm mounting bolt threads and the input pulley shaft threads with an alcohol swab. Allow them to dry and apply blue loctite to the crankarm mounting bolt threads.
  • Page 43: Procedure 7.6 - Replacing The Input Pulley Belt

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.6 - Replacing the Input Pulley Belt WARNING Before continuing with this procedure, review the Warning and Caution statements listed in Section One, Things You Should Know. Remove the rear cover and disconnect the red battery lead from terminal M6 of the lower PCA.
  • Page 44: Procedure 7.7 - Replacing The Generator Pulley Belt

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.7 - Replacing the Generator Pulley Belt WARNING Before continuing with this procedure, review the Warning and Caution statements listed in Section One, Things You Should Know. Remove the rear cover and disconnect the red battery lead from terminal M6 of the lower PCA.
  • Page 45 C524, C524i Elliptical Fitness Crosstrainer 17. Tension both belts per Procedure 5.3. Note the differences between tensioning a new belt and a existing (used) belt. 18. Replace the red battery lead removed in step 1 and check unit operation as described in Section Four.
  • Page 46: Procedure 7.8 - Replacing The Input Pulley Assembly

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.8 - Replacing the Input Pulley Assembly WARNING Before continuing with this procedure, review the Warning and Caution statements listed in Section One, Things You Should Know. Remove the rear cover and disconnect the red battery lead from terminal M6 of the lower PCA.
  • Page 47 C524, C524i Elliptical Fitness Crosstrainer Remove the input pulley assembly. Slide input pulley belt off of the input pulley assembly. Hold the replacement input pulley assembly at it’s mounting position and slide the input belt over and past the pillow block bearing and onto the input pulley assembly.
  • Page 48: Procedure 7.9- Replacing The Step-Up Pulley Assembly

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.9- Replacing the Step-Up Pulley Assembly WARNING Before continuing with this procedure, review the Warning and Caution statements listed in Section One, Things You Should Know. Remove the rear cover and disconnect the red battery lead from terminal M6 of the lower PCA.
  • Page 49: Procedure 7.10 - Replacing A Wheel Assembly

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.10 - Replacing a Wheel Assembly Warning: Care must be taken when work is being performed in the area of the stairarms. Pinch points exist between the stairarm and ramp and between the stairarm and crankarm, when the rear covers are removed.
  • Page 50: Procedure 7.11 - Replacing A Stairarm Pedal

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.11 - Replacing a Stairarm Pedal Loosen and remove the two bolts that fasten the stairarm pedal onto the stairarm. Remove the stairarm pedal from the stairarm. Set the replacement stairarm pedal at it’s mounting position on the stairarm.
  • Page 51: Procedure 7.12 - Replacing A Stairarm

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.12 - Replacing a Stairarm Warning: Care must be taken when work is being performed in the area of the stairarms. Pinch points exist between the stairarm and ramp and between the stairarm and crankarm, when the rear covers are removed.
  • Page 52: Procedure 7.13 - Replacing A Ramp Assembly

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.13 - Replacing a Ramp Assembly Warning: Care must be taken when work is being performed in the area of the stairarms. Pinch points exist between the stairarm and ramp and between the stairarm and crankarm, when the rear covers are removed.
  • Page 53 C524, C524i Elliptical Fitness Crosstrainer Diagram 7.9 - Upper Ramp Mounting Upper Ramp Mounting Bolts Rotate both stairarms forward and place them on the ramp tracks. Replace the left and right rear covers per Procedure 7.15 and check unit operation as described in Section Four.
  • Page 54: Procedure 7.14 - Replacing A Handlebar

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.14 - Replacing a Handlebar Slide the lower handle bar boot up the handlebar to expose the lower handlebar mounting bolts. Remove both of the lower handlebar mounting bolts. See Diagram 7.10. Diagram 7.10 - Lower Handlebar Mounting...
  • Page 55: Procedure 7.15 - Replacing A Main Column

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.15 - Replacing a Main Column Procedure Remove the rear cover and disconnect the red battery lead from terminal M6 of the lower PCA. Attach the anti-static wrist strap to your arm, then connect the ground lead of the wrist strap to the EFX frame.
  • Page 56 C524, C524i Elliptical Fitness Crosstrainer Remove both handlebars per Procedure 7.14. Remove the left and right frame tube per Procedure 7.24. 10. Remove the two bolts and washers that fasten the bottom of the main column to the frame base. See Diagram 7.11. Remove the main column.
  • Page 57: Procedure 7.16 - Replace The Rear Cover

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.16 - Replace the Rear Cover The rear cover is a four piece cover; front, top, left and right sections. If the front cover section is being removed, the frame cover must also be removed (See Diagram 7.12).
  • Page 58 C524, C524i Elliptical Fitness Crosstrainer Diagram 7.13 - Top Cover Section (with right & left cover sections removed) Top Cover Mounting Section Screw Front Cover Frame Section Upright If all four cover sections have been removed, first replace the frame cover and front cover section, then the top cover section and then the left and right cover sections as described below.
  • Page 59: Procedure 7.17 - Replacing A Load Resistor

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.17 - Replacing a Load Resistor Warning When the EFX is operated the load resistors get very hot. Be sure to allow the load resistors enough time to cool before continuing with this procedure.
  • Page 60 C524, C524i Elliptical Fitness Crosstrainer frame upright with the screws removed in step 2. Route the load resistor wires into the slots at the top of the frame upright. This will keep the wires away from all moving parts, such as the stairarms.
  • Page 61: Procedure 7.18 - Replacing A Generator (C524, Only)

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.18 - Replacing a Generator (C524, only) WARNING When the unit is used, stairarms are in motion or the generator is rotated by any means, the generator will produce potentially hazardous voltages even when the battery is disconnected.
  • Page 62 C524, C524i Elliptical Fitness Crosstrainer When the generator belt tension is correct, torque the four generator mounting bolts to 150 inch pounds. Securely tighten the forward nut on the adjustment bolt. Reconnect the red battery lead removed in step 1 and replace the rear cover.
  • Page 63: Procedure 7.19 - Replacing A Generator (C524I, Only)

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.19 - Replacing a Generator (C524i, only) WWARNING When the unit is used, stairarms are in motion or the generator is rotated by any means, the generator will produce potentially hazardous voltages even when the battery is disconnected.
  • Page 64 C524, C524i Elliptical Fitness Crosstrainer Diagram 7.17 - Generator Bearing Clamp Bearing Clamp Bearing Clamp Mounting Screw 10. Replace and tighten the three generator mounting screws removed in step 9. Set the bearing clamp in its mounting position, replace and tighten the two bearing clamp mounting screws removed in step 9.
  • Page 65: Procedure 7.20 - Replacing A Battery (C524, Only)

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.20 - Replacing a Battery (C524, only) Remove the rear cover Disconnect the red battery lead from terminal M6 of the lower PCA and the black battery lead from M7 of the lower PCA. See Diagram 7.5.
  • Page 66 C524, C524i Elliptical Fitness Crosstrainer Diagram 7.19 - Battery Wiring Red Wire Red Dot Positive Terminal Slide the replacement battery into the battery bracket with the battery terminals nearest to the open end of the battery bracket. Fasten the lower PCA and battery assembly to the frame upright with the screws removed in step 4.
  • Page 67: Procedure 7.21 - Replacing A Battery (C524I, Only)

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.21 - Replacing a Battery (C524i, only) Remove the entire rear cover, including the front section of the cover. Disconnect the red battery lead from terminal M6 of the lower PCA and the black battery lead from M7 of the lower PCA of the lower PCA.
  • Page 68 C524, C524i Elliptical Fitness Crosstrainer Diagram 7.21 - Battery Bracket, Front Retaining Bracket Side Bracket Front Retaining Bracket Mounting Remove the nut fastens the front battery retaining bracket. Refer to Diagram 7.18. Carefully, slide the battery out of the battery bracket.
  • Page 69: Procedure 7.22 - Replacing A Power Input Jack Assembly

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.22 - Replacing a Power Input Jack Assembly Remove the rear cover and disconnect the red battery lead from terminal M6 of the lower PCA. Disconnect the J4 connector from the lower PCA. See Diagram 7.18.
  • Page 70 C524, C524i Elliptical Fitness Crosstrainer 11. Replace the red battery lead removed in step 1 and check unit operation as described in Section Four. Page 70...
  • Page 71: Procedure 7.23 - Replacing A Lift Motor

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.23 - Replacing a Lift Motor Remove the left rear cover and disconnect the red battery lead from terminal M6 of the lower PCA. Remove both front covers. Carefully, extract the lift motor cable from the frame access hole and disconnect the lift motor cable from the lift intermediate cable.
  • Page 72: Procedure 7.24 - Replacing A Frame Tube

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.24 - Replacing a Frame Tube Procedure Remove the two screws that fasten the cover near the middle of the main column. Remove the cover. Remove the four bolts and washers that fasten the lower end of the frame tube to the frame base.
  • Page 73: Procedure 7.25 - Replacing A Stairarm Pivot Block

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.25 - Replacing a Stairarm Pivot Block Warning: Care must be taken when work is being performed in the area of the stairarms. Pinch points exist between the stairarm and ramp and between the stairarm and crankarm, when the rear covers are removed.
  • Page 74 C524, C524i Elliptical Fitness Crosstrainer Slide the stairarm pivot block onto the crankarm pin and replace the retaining ring removed in step 4. Slide the stairarm onto the stairarm pivot block. Install and hand tighten the stairarm pivot block mounting hardware. Torque the stairarm pivot block mounting bolt to 15 ft./lbs.
  • Page 75 C524, C524i Elliptical Fitness Crosstrainer Procedure 7.26 - Replacing a Ramp Mounting Bracket Warning: Care must be taken when work is being performed in the area of the stairarms. Pinch points exist between the stairarm and ramp and between the stairarm and crankarm, when the rear covers are removed.
  • Page 76 C524, C524i Elliptical Fitness Crosstrainer Set the replacement mounting bracket at its mounting position on the frame. Apply blue loctite to the ramp mounting bolts removed in step 6. Slide the wave washers onto the mounting bolts and then the shims. Hand start the ramp mounting bolts and then torque them to 35 ft./lbs.
  • Page 77: Procedure 7.27 - Replacing The Prom

    C524, C524i Elliptical Fitness Crosstrainer Procedure 7.27 - Replacing the PROM Anti-static kits (part number 20024-101) can be ordered from Precor. The PROM and the associated printed circuit assembly (PCA) are static sensitive. Anti- static devices must be used and all anti-static precautions must be followed during this procedure.
  • Page 78: Wiring Diagram 8.1 - C524 Self Powered

    C524, C524i Elliptical Fitness Crosstrainer Wiring Diagram 8.1 - C524 Self Powered J3-6 20 Ohm, 300W Load Resistor J3-5 Intermediate Connector Lift Motor Page 78...
  • Page 79 C524, C524i Elliptical Fitness Crosstrainer Block Diagram 8.2 - C524 Self Powered Page 79...
  • Page 80 C524, C524i Elliptical Fitness Crosstrainer Wiring Diagram 8.3 - C524i Self Powered Jack Battery J1-5 J1-6 J1-7 J3-6 J3-5 J3-4 J3-2 J3-3 Lift Motor Intermediate Connector Page 80...
  • Page 81 C524, C524i Elliptical Fitness Crosstrainer Block Diagram 8.4 - C524i Self Powered Page 81...

This manual is also suitable for:

C524i

Table of Contents