12. Disconnect the data cable, from the frame, from the mid-point connector module.
Disconnect the other end of the data cable from the lower PCA.
13. Tape the replacement lower data cable to the lower PCA end of the existing data cable.
Carefully pull the existing lower data cable out of the hole in the frame as you feed the
replacement data cable into the frame. Stop when the replacement data cable appears out
of the hole in the frame.
14. Remove the tape fastening the two data cables and discard the old data cable.
15. Reconnect the data cable to the lower PCA.
16. Connect the data cable to the mid-point connector, place the cables and mid-point
connector in the frame.
17. Carefully, set the outrigger tube in its mounting position and fasten it with the bolts and
clamp removed in step 11.
18. Replace the left, right, top and access panel rear cover sections per Procedure 7.1.
19. Check operation as described in Section Four.
C534i Elliptical Fitness Crosstrainer