Precor C534i Service Manual page 61

Elliptical fitness crosstrainer
Table of Contents

Advertisement

5.
If you are removing the right hand outrigger tube, skip to step 12. If you are removing the left
hand outrigger tube, continue with step 7.
6.
Disconnect the data cable from the upper printed circuit board. If applicable. See Diagram
6.2.
7.
Carefully remove the outrigger tube from the EFX. The data cable is still connected to the
mid-point connector and the lower end of the outrigger tube.
8.
Disconnect the data cable from the mid-point connector.
9.
Remove the data cable from the old outrigger tube and feed it into the replacement outrigger
tube.
10. Connect the data cable to the upper PCA and the mid-point connector.
11. Set the outrigger tube at its mounting position and fasten it with the seven bolts removed in
step 4. Tighten the clamp bolts loosened in step 5.
12. Thoroughly test the EFX per Section Four.