Procedure 7.4
Procedure
Note: Before you install a new data cable, ensure that the data cable is defective. Refer to Pro-
cedure 6.1. The upper data cable is connected to the upper PCA at the rear of the display, and is
then routed down the left outrigger tube. The upper data cable meets the lower data cable at the
bottom of the left outrigger tube. The upper data cable is connected to the lower data cable via a
coupler module. The lower data cable is routed through the frame from the bottom of the left out-
rigger tube to the lower PCA.
Replacing an Upper Data Cable
1.
Remove the display bracket cover and the display rear cover and disconnect the data cable
from the upper PCA. See Diagram 6.2.
2.
Remove the three bolts that fasten the top, remove the four bolts that fasten the bottom and
remove the clamp from the center of the left outrigger tube. See Diagram 6.1. Carefully slide
the outrigger tube a short distance away from the frame to expose the data cable.
3.
Disconnect the data cable, from the outrigger tube, from the mid-point connector module.
Disconnect the other end of the data cable from the upper PCA.
4.
Tape one end of the replacement data cable to the display end of the existing data cable.
Carefully pull the existing upper data cable out of the hole in the frame, near the rear of the
ramp, as you feed the replacement data cable into the upper end of the left outrigger tube.
Stop when the replacement data cable appears out of the bottom of the outrigger tube.
5.
Remove the tape fastening the two data cables and discard the old data cable.
6.
Reconnect the data cable to the rear of the upper PCA and replace the display bracket
cover.
7.
Connect the data cable to the mid-point connector, place the cables and mid-point
connector in the frame.
8.
Skip to step 17.
Replacing the Lower Data Cable
9.
Remove the access panel, top, left and right cover sections per Procedure 7.1.
10. Remove the display bracket cover.
11. Remove the three bolts that fasten the top, remove the four bolts that fasten the bottom and
remove the clamp from the center of the left outrigger tube. See Diagram 6.1. Carefully slide
the outrigger tube a short distance away from the frame to expose the data cable.
- Replacing a Lower or Upper Data Cable