H4: Analog Outputs - YASKAWA CR700 Technical Manual

Hide thumbs Also See for CR700:
Table of Contents

Advertisement

Setting Value
Function
6
DC Injection Braking
Current
7
Torque Detection Level
8
Stall Prevent Level
During Run
C
Overload Detection
Level
D
Frequency Bias
E
Motor Temperature
(PTC Input)
F
Not Used
10
Forward Torque Limit
11
Reverse Torque Limit
12
Regenerative Torque
Limit
14
Torque Compensation
15
General Torque Limit
1F
Not Used

H4: Analog Outputs

No.
Name
(Hex.)
H4-01
Terminal FM Analog
Output Select
(041D)
H4-02
Terminal FM Analog
Output Gain
(041E)
RUN
H4-03
Terminal FM Analog
Output Bias
(041F)
RUN
H4-04
Terminal AM Analog
Output Select
(0420)
H4-05
Terminal AM Analog
Output Gain
(0421)
RUN
H4-06
Terminal AM Analog
Output Bias
(0422)
RUN
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
V/f
CL-V/f
OLV
CLV
AOLV
Enters a signal to adjust the current level used for DC Injection Braking when the drive rated output current is
100%.
V/f
CL-V/f
OLV
CLV
AOLV
Enters a signal to adjust the overtorque detection level.
V/f
CL-V/f
OLV
CLV
AOLV
Enters a signal to adjust the stall prevention level during run if the drive rated current is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Enters the overload detection level.
V/f
CL-V/f
OLV
CLV
AOLV
Enters the bias value added to the frequency reference as a percentage of the maximum output frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Uses the motor Positive Temperature Coefficient (PTC) thermistor to prevent heat damage to the motor as a
percentage of the current value when the 10 V analog signal is input.
V/f
CL-V/f
OLV
CLV
AOLV
Use this setting for unused terminals or to use terminals in through mode.
V/f
CL-V/f
OLV
CLV
AOLV
Enters the forward torque limit if the motor rated torque is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Enters the load torque limit if the motor rated torque is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Enters the regenerative torque limit if the motor rated torque is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Enters the torque compensation value if the motor rated torque is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Enters the torque limit that is the same for all quadrants for forward, reverse, and regenerative operation if the
motor rated torque is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Use this setting for unused terminals or to use terminals in through mode.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the monitor number to send from MFAO terminal FM.
Set the x-xx part of the Ux-xx [Monitor]. For example, set H4-01 = 102 to monitor U1-
02 [Output Frequency].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain of the Ux-xx monitor signal set in H4-01 [terminals FM Monitor
Selection].
When an output for monitoring items is 100%, this parameter sets the analog signal
output level from the FM terminal at 10 V as 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the bias of the Ux-xx monitor signal set in H4-01 [Terminal FM Analog Output
Select].
When an output for monitoring items is 0%, this parameter sets the analog signal output
level from the FM terminal at 10 V as 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the monitoring number to be output from the MFAO terminal AM.
Set the x-xx part of the Ux-xx [Monitor]. For example, set H4-04 = 103 to monitor U1-
03 [Output Current].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain of the Ux-xx monitor signal set in H4-04 [terminals AM Monitor
Selection].
When an output for monitoring items is 100%, this parameter sets the analog signal
output level from the AM terminal at 10 V as 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the bias of the Ux-xx monitor signal set in H4-04 [terminals AM Monitor
Selection].
When an output for monitoring items is 0%, this parameter sets the analog signal output
level from the AM terminal at 10 V as 100%.
10.10 H: Terminal Functions
Description
Ref.
731
731
214
226
732
732
213
226
732
732
733
733
734
734
734
734
734
Default
Ref.
(Range)
102
736
(000 - 999)
100.0%
736
(-999.9 - +999.9%)
0.0%
736
(-999.9 - +999.9%)
103
736
(000 - 999)
50.0%
736
(-999.9 - +999.9%)
0.0%
737
(-999.9 - +999.9%)
511
10