Appendix B — Bluetooth Configuration Commands and Specifications
124
Example
Connectable On/Off
Command
Description
Example
Specify Page Scan Timing
Command
Description
Default
Example
Note: To enable scanning, the values for Interval and Window
must be in the range of 18 to 4096. The Window value must be
less than the Interval value. Both values must be zero to disable
scanning.
Note: Modifying Page Scan Timing can improve connection
times, but may adversely affect battery performance.
Enable Discoverable
Command
Description
Example
"S3Acme Printer<CR>"
C0 <ON|OFF><CR>
Sets the device into "connectable" mode
"C0OFF<CR>" — Become non-connectable
"C0ON<CR>" — Become connectable
C1<Page_Scan_Interval>,<Page_Scan_Window><
CR>
Sets the Page Scan timing parameters
4096,18
"C11024,512<CR>"
D0 <ON|OFF><CR>
Sets the device into "discoverable" mode
"D0OFF<CR>" — Become non-discoverable
"D0ON<CR>" — Become discoverable
6820 Series 80-Column Printer User's Manual